Background And Objective: Dynamic lung hyperinflation (DLH) can play a central role in exertional dyspnoea in patients with COPD. Chest radiography is the basic tool for assessing static lung hyperinflation in COPD. However, the predictive capacity of DLH using chest radiography remains unknown. This study was conducted to determine whether DLH can be predicted by measuring the height of the right diaphragm (dome height) on chest radiography.

Methods: This single-centre, retrospective cohort study included patients with stable COPD with pulmonary function test, cardiopulmonary exercise test, constant load test and pulmonary images. They were divided into two groups according to the median of changes of inspiratory capacity (ΔIC=IC lowest - IC at rest). The right diaphragm dome height and lung height were measured on plain chest radiography.

Results: Of the 48 patients included, 24 were classified as having higher DLH (ΔIC ≤-0.59 L from rest; -0.59 L, median of all) and 24 as having lower DLH. Dome height correlated with ΔIC (r=0.66, p<0.001). Multivariate analysis revealed that dome height was associated with higher DLH independent of % low attenuation area on chest computed tomography and forced expiratory volume in 1 s (FEV) % predicted. Furthermore, the area under the receiver operating characteristic curve of dome height to predict higher DLH was 0.86, with sensitivity and specificity of 83% and 75%, respectively, at a cut-off of 20.5 mm. Lung height was unrelated to ΔIC.

Conclusion: Diaphragm dome height on chest radiography may adequately predict higher DLH in patients with COPD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10291310PMC
http://dx.doi.org/10.1183/23120541.00079-2023DOI Listing

Publication Analysis

Top Keywords

dome height
16
diaphragm dome
12
chest radiography
12
lung hyperinflation
12
height chest
8
dynamic lung
8
hyperinflation copd
8
height
6
chest
5
dlh
5

Similar Publications

The study presents a numerical parametric investigation of flow structures in channels with a longitudinal-radial profile zR = Const and a spherical dome at the base. The goal of the study was to examine the flow structures in these channels depending on the exponent N of the profile and the height of the dome, to determine the conditions that provide optimal centripetal swirling flow, analogous to blood flow in the heart chambers and major vessels. The investigation was conducted using a comparative analysis of flow structures in channel configurations zR = Const, carried out in two stages.

View Article and Find Full Text PDF

Multi-layer conductive structures, especially those with features like bolt holes, are vulnerable to hidden corrosion and cracking, posing a serious threat to equipment integrity. Early defect detection is vital for implementing effective maintenance strategies. However, the subtle signals produced by these defects necessitate highly sensitive non-destructive testing (NDT) techniques.

View Article and Find Full Text PDF

Development of Hemispherical 3D Models of Human Brain and B Cell Lymphomas Using On-Chip Cell Dome System.

Bioengineering (Basel)

December 2024

Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka 560-8531, Osaka, Japan.

Lymphocytes are generally non-adherent. This makes it challenging to fabricate three-dimensional (3D) structures mimicking the three-dimensional lymphoma microenvironment in vivo. This study presents the fabrication of a hemispherical 3D lymphoma model using the on-chip Cell Dome system with a hemispherical cavity (1 mm in diameter and almost 300 µm in height).

View Article and Find Full Text PDF

Introduction: The aim of this study was to differentiate amelanotic choroidal lesions - amelanotic choroidal melanoma, choroidal metastasis, and choroidal granuloma using multimodal imaging.

Methods: Retrospective comparative chart review was done. Patients diagnosed with the abovementioned choroidal lesions from 2015 to 2022 were included.

View Article and Find Full Text PDF

Introduction And Importance: There are few cases of multiple simultaneous anterior communicating artery (AComA) aneurysms with A2 triplication and AComA duplication.

Cases Presentation: (1) A fenestrated AComA with a saccular aneurysm (neck diameter 9 mm; dome height 8 mm) projecting superiorly from the distal AComA branch, as well as an anomalous artery arising from the posterior surface of the same AComA. (2) A duplicate AComA with a saccular aneurysm (neck diameter of 5 mm; dome height of 9 mm) projecting superioposteriorly from the distal AComA branch, as well as an anomalous artery arising from the anterior surface of the same AComA was diagnosed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!