Glass fiber-reinforced polymer (GFRP) has superior characteristics over traditional steel, such as lightweight, high strength, corrosion resistance and high durability. GFRP bars can be a useful alternative to steel bars in structures, specifically those in highly corrosive environments, as well as structures subjected to high compressive pressure such as bridge foundations. Digital image correlation (DIC) technology is used to analyze the strain evolution of GFRP bars under compression. It can be seen from using DIC technology that the surface strain of GFRP reinforcement is uniformly distributed and increases approximately linearly, and brittle splitting failure of GFRP bars happens due to locally occurring high strain at the failure stage. Moreover, there are limited studies on the use of distribution functions to describe the compressive strength and elastic modulus of GFRP. In this paper, Weibull distribution and gamma distribution are used to fit the compressive strength and compressive elastic modulus of GFRP bars. The average compressive strength is 667.05 MPa and follows Weibull distribution. Moreover, the average compressive elastic modulus is 47.51 GPa and follows gamma distribution. In order to verify that GFRP bars still have certain strength under compressive conditions, this paper provides a parameter reference for their large-scale application.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301421PMC
http://dx.doi.org/10.3390/polym15122651DOI Listing

Publication Analysis

Top Keywords

gfrp bars
24
compressive strength
12
elastic modulus
12
gfrp
9
compressive
8
glass fiber-reinforced
8
fiber-reinforced polymer
8
polymer gfrp
8
dic technology
8
modulus gfrp
8

Similar Publications

In this study, the short-beam shear strength (SBSS) retention of two types of glass fiber-reinforced polymer (GFRP) bars-sand-coated (SG) and ribbed (RG)-was subjected to alkaline, acidic, and water conditions for up to 12 months under both high-temperature and ambient laboratory conditions. Comparative assessments were also performed on older-generation sand-coated (SG-O) and ribbed (RG-O1 and RG-O2) GFRP bars exposed to identical conditions. The results demonstrate that the new-generation GFRP bars, SG and RG, exhibited significantly better durability in harsh environments and exhibited SBSS retentions varying from 61 to 100% in SG and 90-98% in RG under the harshest conditions compared to 56-69% in SG-O, 71-80% in RG-O1, and 74-88% in RG-O2.

View Article and Find Full Text PDF

Effect of GFRP Stirrup Confinement on the Bond Strength of GFRP-RC Beams.

Int J Concr Struct Mater

December 2024

Civil and Architectural Engineering Department, University of Miami, Coral Gables, FL 33146 USA.

The current provisions for development length in the ACI 440.11 code disregard the confinement effect provided by stirrups on the bond strength of longitudinal bars and require splice lengths that pose implementation challenges. Given the significant improvement in GFRP material properties, this study investigated the bond strength of sand-coated GFRP bars and proposed a new factor to include the effect of stirrup confinement on the bond-strength provisions.

View Article and Find Full Text PDF

In modern constructions, the use of composite column has become widespread used due to the modern requirements of tall buildings for reducing column cross-sections and construction dead loads. To verify the use of alternative materials employed in construction instead of steel sections, GFRP I-section was utilized in this study for this purpose due to its properties like light weight, corrosion resistance and high strength. The research aims to study the influence of using different types of encased I-section (steel and GFRP) in addition to steel bars in the reinforced concrete composite columns.

View Article and Find Full Text PDF

Evaluation of 3-Point and 4-Point Bending Tests for Tensile Strength Assessment of GFRP Bars.

Materials (Basel)

October 2024

Department of Civil and Environmental Engineering, University of Waterloo, 200 University Ave. West, Waterloo, ON N2L 3G1, Canada.

Glass Fiber Reinforced Polymer (GFRP) bars are used as reinforcement for structural concrete, especially in cases where corrosion of traditional steel reinforcement is a problem. The tensile strength of these reinforcing bars is the primary characteristic on which the design of concrete members reinforced with GFRP bars relies. Determination of the tensile strength of the bars using a direct tensile test is a time and resource-intensive task and therefore is not routinely conducted for quality control.

View Article and Find Full Text PDF

In this study, the transverse shear strength (TSS) retention of two types of new-generation glass fiber-reinforced polymer (GFRP) bars, namely ribbed (RB) and sand-coated (SC) bars, was investigated under alkaline, acidic, and marine conditions in both high-temperature and laboratory environments for up to one year. The ribbed GFRP bars exhibited no notable reduction in strength under ambient conditions after 12 months, but under high-temperature conditions (60 °C), they showed TSS reductions of 10.6%, 9.

View Article and Find Full Text PDF