The large-scale use of sulfonamide antimicrobials in human and veterinary medicine has seriously endangered the ecological environment and human health. The objective of this study was to develop and validate a simple and robust method for the simultaneous determination of seventeen sulfonamides in water using ultra-high performance liquid chromatography-tandem mass spectrometry coupled with fully automated solid-phase extraction. Seventeen isotope-labeled internal standards for sulfonamides were used to correct matrix effects. Several parameters affecting extraction efficiency were systematically optimized, and the enrichment factors were up to 982-1033 and only requiring about 60 min per six samples. Under the optimized conditions, this method manifested good linearity (0.05-100 μg/L), high sensitivity (detection limits: 0.01-0.05 ng/L), and satisfactory recoveries (79-118%) with acceptable relative standard deviations (0.3-14.5%, = 5). The developed method can be successfully utilized for the determination of 17 sulfonamides in pure water, tap water, river water, and seawater. In total, six and seven sulfonamides were detected in river water and seawater, respectively, with a total concentration of 8.157-29.676 ng/L and 1.683-36.955 ng/L, respectively, and sulfamethoxazole was the predominant congener.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304559PMC
http://dx.doi.org/10.3390/molecules28124694DOI Listing

Publication Analysis

Top Keywords

automated solid-phase
8
method simultaneous
8
simultaneous determination
8
sulfonamide antimicrobials
8
river water
8
water seawater
8
seawater total
8
water
6
solid-phase extraction-uplc-ms/ms
4
method
4

Similar Publications

4D-printed programmable sample-/eluent-actuated solid-phase extraction device for trace metal analysis.

Anal Chim Acta

January 2025

Department of Chemistry, National Chung Hsing University, Taichung City, 402202, Taiwan, ROC. Electronic address:

Background: To integrate valves, manifolds, and solid-phase extraction (SPE) columns into a compact device is technically difficult. Four-dimensional printing (4DP) technologies, employing stimuli-responsive materials in three-dimensional printing (3DP), are revolutionizing the fabrication, functionality, and applicability of stimuli-responsive analytical devices that can show time-dependent shape programming to enable more complex geometric designs and functions. However, 4D-printed stimuli-responsive actuators and valves utilized to control flowing streams in SPE applications remain rare.

View Article and Find Full Text PDF

Objectives: External quality assessment (EQA) programs play a pivotal role in harmonizing laboratory practices, offering users a benchmark system to evaluate their own performance and identify areas requiring improvement. The objective of this study was to go through and analyze the UK NEQAS "Immunology, Immunochemistry and Allergy" EQA reports between 2012 and 2021 to assess the overall level of harmonization in autoimmune diagnostics and identify areas requiring improvement for future actions.

Methods: The EQA programs reviewed included anti-nuclear (ANA), anti-dsDNA, anti-centromere, anti-extractable nuclear antigen (ENA), anti-phospholipids, anti-neutrophil cytoplasm (ANCA), anti-proteinase 3 (PR3), anti-myeloperoxidase (MPO), anti-glomerular basement membrane (GBM), rheumatoid factor (RF), anti-citrullinated protein antibodies (ACPA), mitochondrial (AMA), liver-kidney-microsomal (LKM), smooth muscle (ASMA), APCA, and celiac disease antibodies.

View Article and Find Full Text PDF

Mycotoxins are detectable in 60-80% of food crops, posing significant threats to human health and food security, and causing substantial economic losses. Most mitigation approaches focus on detecting mycotoxins with standard methods based on liquid chromatography coupled with mass spectrometry (LC-MS). Typical MS methods require extensive sample preparation and clean-up due to the matrix effect, followed by time-consuming LC separation, complicating the analysis process and limiting analytical throughput.

View Article and Find Full Text PDF

ConspectusStructural DNA nanotechnology offers a unique self-assembly toolbox to construct soft materials of arbitrary complexity, through bottom-up approaches including DNA origami, brick, wireframe, and tile-based assemblies. This toolbox can be expanded by incorporating interactions orthogonal to DNA base-pairing such as metal coordination, small molecule hydrogen bonding, π-stacking, fluorophilic interactions, or the hydrophobic effect. These interactions allow for hierarchical and long-range organization in DNA supramolecular assemblies through a DNA-minimal approach: the use of fewer unique DNA sequences to make complex structures.

View Article and Find Full Text PDF

An automated method was developed to simultaneously measure primary amines and short-chain aldehydes emission from foam and rubber samples in one experiment. The technique involved dynamic solid-phase microextraction (SPME) on-fiber derivatization coupled with a flow-cell unit. The parameters of the dynamic SPME on-fiber derivatization method were optimized, including SPME coating, derivatization agents loading temperature, loading time, and dynamic SPME extraction time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!