A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Humidity-Sensing Mattress for Long-Term Bedridden Patients with Incontinence-Associated Dermatitis. | LitMetric

Humidity-Sensing Mattress for Long-Term Bedridden Patients with Incontinence-Associated Dermatitis.

Micromachines (Basel)

Center of Excellence in Creative Engineering Design and Development, Faculty of Engineering, Thammasat University, Pathum Thani 12121, Thailand.

Published: May 2023

Designing new medical devices with advanced humidity sensors is of great significance for patients with incontinence-associated dermatitis (IAD). The primary goal of this study is to test the humidity-sensing mattress system for patients with IAD in clinical settings. The design of the mattress is set at 203 cm, with 10 × 3 sensors, dimensions of 19 × 32 cm, and a weighted bearing of 200 kg. The main sensors consist of a humidity-sensing film, a thin-film electrode (6 × 0.1 mm), and a glass substrate (500 nm). The sensitivity of the test mattress system showed that the resistance-humidity sensor was at a temperature of 35 °C (V0 = 30 V, V0 = 350 mV), with slope at 1.13 V/fF, f = 1 MHz, 20-90% RH, and a response time of 20 s at 2 μm. In addition, the humidity sensor reached 90% RH, with a response time of less than 10 s, a magnitude of 107-104 Ω, 1 mol%, CrO1.5, and FO1.5, respectively. This design is not only a simple, low-cost medical sensing device, but also opens a new pathway for developing humidity-sensing mattresses in the field of flexible sensors, wearable medical diagnostic devices, and health detection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10302182PMC
http://dx.doi.org/10.3390/mi14061178DOI Listing

Publication Analysis

Top Keywords

humidity-sensing mattress
8
patients incontinence-associated
8
incontinence-associated dermatitis
8
mattress system
8
response time
8
humidity-sensing
4
mattress long-term
4
long-term bedridden
4
bedridden patients
4
dermatitis designing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!