A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quad-Band Metamaterial Perfect Absorber with High Shielding Effectiveness Using Double X-Shaped Ring Resonator. | LitMetric

This study assesses quad-band metamaterial perfect absorbers (MPAs) based on a double X-shaped ring resonator for electromagnetic interference (EMI) shielding applications. EMI shielding applications are primarily concerned with the shielding effectiveness values where the resonance is uniformly or non-sequentially modulated depending on the reflection and absorption behaviour. The proposed unit cell consists of double X-shaped ring resonators, a dielectric substrate of Rogers RT5870 with 1.575 mm thickness, a sensing layer, and a copper ground layer. The presented MPA yielded maximum absorptions of 99.9%, 99.9%, 99.9%, and 99.8% at 4.87 GHz, 7.49 GHz, 11.78 GHz, and 13.09 GHz resonance frequencies for the transverse electric (TE) and transverse magnetic (TM) modes at a normal polarisation angle. When the electromagnetic (EM) field with the surface current flow was investigated, the mechanisms of quad-band perfect absorption were revealed. Moreover, the theoretical analysis indicated that the MPA provides a shielding effectiveness of more than 45 dB across all bands in both TE and TM modes. An analogous circuit demonstrated that it could yield superior MPAs using the ADS software. Based on the findings, the suggested MPA is anticipated to be valuable for EMI shielding purposes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303373PMC
http://dx.doi.org/10.3390/ma16124405DOI Listing

Publication Analysis

Top Keywords

shielding effectiveness
12
double x-shaped
12
x-shaped ring
12
emi shielding
12
quad-band metamaterial
8
metamaterial perfect
8
ring resonator
8
shielding applications
8
999% 999%
8
shielding
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!