. Non-coplanar arc geometry optimizations that take advantage of beam's eye view (BEV) geometric overlap information have been proven to reduce dose to healthy organs-at-risk (OARs). Recently, a metric called mean arc distance (MAD) has been developed that quantifies the arc geometry sampling of 4space. The purpose of this research is to combine improved BEV overlap information with MAD to generate static couch lung stereotactic body radiotherapy (SBRT) treatment plans deliverable on a C-arm linear accelerator.. An algorithm utilizing the Moller-Trumbore ray-triangle intersection method was employed to compute a cost surrogate for dose to overlapping OARs using distances interpolated onto a PDD. Cost was combined with MAD for 100 000 random combinations of arc trajectories. A pathfinding algorithm for arc selection was created, balancing the contributions of MAD and 4cost for the final trajectory. This methodology was evaluated for 18 lung SBRT patients. Cases were also planned with arcs from a clinical treatment template protocol for dosimetric and plan quality comparison. Results were evaluated using dose constraints in the context of RTOG0915.. Five of six OARs had maximum dose reductions when planned with the arc trajectory optimization algorithm. Significant maximum dose reductions were found for esophagus (7.41 ± 0.91 Gy,= 0.00019), trachea (5.56 ± 1.55 Gy,= 0.0025), spinal cord (2.87 ± 1.13 Gy,= 0.039), large bronchus (3.47 ± 1.49 Gy,= 0.0075), and aorta (3.13 ± 0.99 Gy,= 0.012). Mean dose to contralateral lung was also significantly reduced (0.50 ± 0.06 Gy,= 0.00019). There were two significant increases in OAR doses: mean dose to ipsilateral lung (0.40 ± 0.09,= 0.00086) and V5to ipsilateral lung (1.95 ± 0.70%,= 0.011). Paddick conformity index increased by 0.03 ± 0.02 (= 0.14), remaining below a limit of 1.2 for both techniques.. Static couch non-coplanar optimization yielded maximum dose reductions to OARs while maintaining target conformity for lung SBRT.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ace23fDOI Listing

Publication Analysis

Top Keywords

static couch
12
lung sbrt
12
maximum dose
12
dose reductions
12
couch non-coplanar
8
non-coplanar arc
8
arc selection
8
sbrt treatment
8
arc geometry
8
dose
8

Similar Publications

Noncoplanar arc optimization has been shown to reduce OAR doses in SRS/SRT and has the potential to reduce doses to OARs in SBRT. Extracranial targets have additional considerations, including large OARs and, in the case of the liver, volume constraints on the healthy liver. Considering pathlengths through OARs that encompass target volumes may lead to specific dose reductions as in the encompassing healthy liver tissue.

View Article and Find Full Text PDF

Purpose: The purpose of this study is to evaluate the dosimetric and treatment delivery characteristics of volumetric modulated arc therapy technique (VMAT)-based craniospinal axis irradiation (CSI) between ring gantry Halcyon (HAL) and C-arm based Novalis Tx (NTx) linear accelerator. Set-up margin and treatment delivery time for both machines were also taken into account.

Materials And Methods: Fifteen patients, 4 females and 11 males treated between March 2019 and February 2022 within the age group 4-56 years simulated in the supine position and were planned for multiple isocentre VMAT technique in ring gantry Halcyon and C-Arm Novalis linear accelerator for 6FFF and 6 MV flatten beam energy.

View Article and Find Full Text PDF

Evaluation of 2D ion chamber arrays for patient specific quality assurance using a static phantom at a 0.35 T MR-Linac.

Z Med Phys

January 2024

Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany.

Introduction: Patient specific quality assurance (QA) in MR-Linacs can be performed with MR-compatible ion chamber arrays. However, the presence of a static magnetic field can alter the angular response of such arrays substantially. This works investigates the suitability of two ion chamber arrays, an air-filled and a liquid-filled array, for patient specific QA at a 0.

View Article and Find Full Text PDF

Commissioning of a RayStation structure template for the iBEAM evo Couchtop.

Phys Eng Sci Med

December 2023

South Western Sydney Cancer Services, Sydney, Australia.

Accurate radiotherapy treatment planning requires attenuation through the treatment couch to be accounted for in dose calculation. This is commonly performed by using contouring tools to add a virtual structure in the shape of the treatment couch and assigning the preferred absorption properties. The RayStation treatment planning system (TPS) allows users to assign a material that comprises both an elemental structure and a physical density.

View Article and Find Full Text PDF

. Non-coplanar arc geometry optimizations that take advantage of beam's eye view (BEV) geometric overlap information have been proven to reduce dose to healthy organs-at-risk (OARs). Recently, a metric called mean arc distance (MAD) has been developed that quantifies the arc geometry sampling of 4space.

View Article and Find Full Text PDF