Significance: When worn for myopia control in children, soft multifocal contact lenses with a +2.50 D add reduced the accommodative response over a 3-year period, but wearing them for more than 4 years did not affect accommodative amplitudes, lag, or facility.
Purpose: This study aimed to compare the accommodative response to a 3D stimulus between single-vision, +1.50-D add, and +2.50-D add multifocal contact lens wearers during 3 years of contact lens wear and then to compare accommodative amplitude, lag, and facility between the three groups after an average of 4.7 years of wear.
Methods: Bifocal Lenses In Nearsighted Kids study participants aged 7 to 11 years old were randomly assigned to wear single-vision, +1.50-D add, or +2.50-D add soft contact lenses (CooperVision, Pleasanton, CA). The accommodative response to a 3D stimulus was measured at baseline and annually for 3 years. After 4.7 years, we measured objective accommodative amplitudes, lead/lag, and binocular facility with ±2.00-D flippers. We compared the three accommodative measures using multivariate analysis of variance (MANOVA), adjusting for clinic site, sex, and age group (7 to 9 or 10 to 11 years).
Results: The +2.50-D add contact lens wearers exhibited lower accommodative response than the single-vision contact lens wearers for 3 years, but the +1.50-D add contact lens wearers exhibited only lower accommodative response than did the single-vision contact lens wearers for 2 years. After adjustment for clinic site, sex, and age group, there were no statistically significant or clinically meaningful differences between the three treatment groups for accommodative amplitude (MANOVA, P = .49), accommodative lag (MANOVA, P = .41), or accommodative facility (MANOVA, P = .87) after an average of 4.7 years of contact lens wear.
Conclusions: Almost 5 years of multifocal contact lens wear did not affect the accommodative amplitude, lag, or facility of children.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10527037 | PMC |
http://dx.doi.org/10.1097/OPX.0000000000002040 | DOI Listing |
Retina
October 2024
Department of Ophthalmology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China.
Purpose: The research investigates the efficacy of hydroxypropyl methylcellulose (HPMC) treatment in facilitating the development of compact water droplets on the rear surface of synthetic lenses with capsule imperfections during the process of fluid-air exchange.
Method: This study examined four patients with intraocular lens (IOL) implants and posterior capsule defects who experienced the formation of dense water droplets on the posterior surface following fluid-air exchange. When this occurrence obstructs fundus visualization during surgery, it is recommended to suspend the surgical procedure.
Eye Contact Lens
December 2024
Department of Ophthalmology (Z.O.O.), Gaziantep State Hospital, Gaziantep, Turkey; Department of Ophthalmology (L.D.), Niğde Ömer Halisdemir University, Niğde, Turkey; and Department of Ophthalmology (I.E.Y.), Gaziantep Dr. Ersin Arslan Training and Research Hospital, Gaziantep, Turkey.
Purpose: We aimed to compare the answers given by ChatGPT, Bard, and Copilot and that obtained from the American Academy of Ophthalmology (AAO) website to patient-written questions related to keratoconus in terms of accuracy, understandability, actionability, and readability to find out whether chatbots can be used in patient education.
Methods: Twenty patient-written questions obtained from the AAO website related to keratoconus were asked to ChatGPT, Bard, and Copilot. Two ophthalmologists independently assessed the answers obtained from chatbots and the AAO website in terms of accuracy, understandability, and actionability according to the Structure of Observed Learning Outcome taxonomy, Patient Education Materials Assessment Tool-Understandability, and Patient Education Materials Assessment Tool-Actionability tests, respectively.
Eye Contact Lens
December 2024
Department of Ophthalmology (E.D., Z.B.S., E.E.E.O., H.O.), Istanbul Medeniyet University Goztepe Prof. Dr. Suleyman Yalçin City Hospital, Istanbul, Turkey; Goztepe Prof. Dr. Suleyman Yalçin City Hospital (O.F.Y.), Department of Ophthalmology, Istanbul, Turkey; and Haydarpasa Numune Education and Research Hospital (M.S.M.), University of Health Sciences, Sadik Eratik Eye Institute, Istanbul, Turkey.
Objectives: This study compares the cosmetic and functional outcomes of corneal tattooing/keratopigmentation and ocular prostheses in rehabilitating disfigured eyes, focusing on esthetic appearance and emotional well-being.
Methods: Ninety-two patients were included: 48 received corneal tattooing, and 44 were fitted with ocular prostheses. Anophthalmic surgery was indicated for trauma, painful blind eye, endophthalmitis, tumor, and corneal ulcer, while corneal tattooing was performed for trauma, corneal ulcer, and endophthalmitis.
Eye Contact Lens
December 2024
Department of Ophthalmology, Massachusetts Eye & Ear, Harvard University, Boston, MA.
The design of the prosthetic replacement of the ocular surface ecosystem (PROSE) device allows it to serve as a novel drug delivery system. In this article, we describe the off-label administration of amphotericin B and cenegermin by instillation in the PROSE device reservoir for the treatment of Candida keratitis in the setting of a persistent epithelial defect.
View Article and Find Full Text PDFCurr Drug Deliv
January 2025
Department of Pharmaceutics, Y. B. Chavan College of Pharmacy, Aurangabad, India.
Pharmaceutical giants (e.g., Ashland, Bausch & Lomb, Johnson & Johnson, Medtronic, Neurelis, etc.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!