One-Step Quantification of anti-Covid-19 Antibodies via Dual Affinity Ratiometric Quenching Assays.

Anal Chem

Department of Chemical & Biomolecular Engineering, North Carolina State University, 911 Partners Way, Raleigh, North Carolina 27695, United States.

Published: July 2023

The global pandemic caused by acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has affected millions of people and paralyzed healthcare systems worldwide. Developing rapid and accurate tests to detect and quantify anti-SARS-CoV-2 antibodies in complex fluids is critical to (i) track and address the spread of SARS-CoV-2 variants with different virulence and (ii) support the industrial manufacturing and clinical administration of anti-SARS-CoV-2 therapeutic antibodies. Conventional immunoassays, such as lateral flow, ELISA, and surface plasmon resonance (SPR), are either qualitative or, when quantitative, are laborious and expensive and suffer from high variability. Responding to these challenges, this study evaluates the performance of the Dual-Affinity Ratiometric Quenching (DARQ) assay for the quantification of anti-SARS-CoV-2 antibodies in bioprocess harvests and intermediate fractions (i.e., a Chinese hamster ovary (CHO) cell culture supernatant and a purified eluate) and human fluids (i.e., saliva and plasma). Monoclonal antibodies targeting the SARS-CoV-2 nucleocapsid as well as the spike protein of the delta and omicron variants are adopted as model analytes. Additionally, conjugate pads loaded with dried protein were studied as an at-line quantification method that can be used in clinical or manufacturing laboratories. Our results indicate that the DARQ assay is a highly reproducible (coefficient of variation ∼0.5-3%) and rapid (<10 min) test, whose sensitivity (∼0.23-2.5 ng/mL), limit of detection (23-250 ng/mL), and dynamic range (70-1300 ng/mL) are independent of sample complexity, thus representing a valuable tool for monitoring anti-SARS-CoV-2 antibodies.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.3c01266DOI Listing

Publication Analysis

Top Keywords

ratiometric quenching
8
anti-sars-cov-2 antibodies
8
darq assay
8
antibodies
5
one-step quantification
4
quantification anti-covid-19
4
anti-covid-19 antibodies
4
antibodies dual
4
dual affinity
4
affinity ratiometric
4

Similar Publications

Accurately monitoring the content of Cu and Hg in real samples and biological systems is of great significance in ensuring food safety and human health. Therefore, developing efficient methods for simultaneously detecting Cu and Hg is of great significance in living organisms and real samples. In this work, a bifunctional ratiometric and colorimetric fluorescent bio-sensor DPT-1, was designed and synthesized using triphenylamine to specifically and concurrently detect Cu and Hg exhibited varying degrees of fluorescence quenching through "turn-off" fluorescence.

View Article and Find Full Text PDF

Copper-based fluorescent nanozyme used to construct a ratiometric sensor for visual detection of thiophanate methyl.

Talanta

December 2024

Key Laboratory of Catalytic Conversion and Clean Energy in Universities of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu City, 273165, Shandong, China. Electronic address:

Although nanozyme has shown great potential in designing fluorescent assays for pesticide residue, most of them are based on single emission, thus affecting the detection accuracy. Herein, a copper-based fluorescent nanozyme (Cu-BH) synthesized with dual-ligand, integrating fluorescence and oxidase-mimic into one spherical nanomaterial, was used firstly to establish a ratiometric approach for visual detection of thiophanate methyl (TM). Cu-BH possesses excellent oxidase-like activities, triggering the oxidation of colorless o-phenylenediamine (OPD) into yellow luminescent products (oxOPD, λem = 564 nm).

View Article and Find Full Text PDF

In this paper, we report on the sensing role of the 1,2,3-triazol unit in a 1,4-diyl arrangement in a fully π-conjugated fluorescent probe 1 (cf. Scheme 1) towards the fluorometric detection of 3d metal ions. The 1,2,3-triazol-1,4-diyl-fluoroionophore 1 was designed in a donor(D)-acceptor(A) arrangement with a 1,2,3-triazol unit as a π-linker between a terpyridine (A) ionophore and a diethylaminocoumarin (D) fluorophore to study the fluorescence behavior towards the divalent 3d metal ions Mn, Fe, Co, Ni, Cu and Zn.

View Article and Find Full Text PDF

Mercury (Hg) has been recognized as a global pollutant with a toxic, mobile, and persistent nature. It adversely affects the ecosystem and human health. Already developed biosensors for Hg detection majorly suffer from poor sensitivity and specificity.

View Article and Find Full Text PDF

A ratiometric fluorescence-photothermal dual-mode assay method is constructed for the detection of butyrylcholinesterase (BChE) activity based on time-resolved levodopa (L-DOPA) cascade polymerization. First, a newly designed bimetallic metal-organic framework (MOF), Eu/Co-DPA (DPA: pyridine-2,6-dicarboxylic acid), is screened out as a fluorescent nanozyme with high catalytic activity and superior luminescence properties. In the presence of boric acid (BA), L-DOPA forms BA-esterified L-DOPA, which is catalyzed by Eu/Co-DPA to form the oligomers with strong blue fluorescence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!