A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and Laboratory Evaluation of a Simple, Field-Applicable Coproantigen Enzyme-Linked Immunosorbent Assay for Diagnosis of Taeniasis in Northern Peru. | LitMetric

Coproantigen detection by enzyme-linked immunosorbent assay (coAg ELISA) is a vital tool for detecting and treating cases of Taenia solium taeniasis. However, the assay's procedures require costly materials and sophisticated equipment, which are typically inaccessible in rural settings where the disease is endemic. To overcome these barriers, we developed and evaluated a field-applicable coAg ELISA. The field coAg ELISA was developed and evaluated across four phases using known positive and negative stool samples collected from northern Peru. Phase I focused on field assay development, phase II on a small-scale performance evaluation, phase III on a large-scale evaluation, and phase IV on the use and reliability of a colorimetric scale card. All samples were processed using the field and standard assay procedures and compared using signal-to-noise ratios, correlation tests, performance characteristics, and agreement statistics where appropriate. The field coAg ELISA using reagents stored at -20°C and commercially available water and milk powder, and relying on spontaneous separation of the supernatant, had performance comparable to the standard assay. The field coAg ELISA was strongly correlated with the standard in both the small- and large-scale laboratory evaluation ( = 0.99 and  = 0.98, respectively). Finally, the field assay had an almost perfect agreement between independent readers (kappa = 0.975) and between each reader and the spectrophotometer. The field coAg ELISA demonstrated performance comparable to the standard, providing a low-cost alternative to the standard assay for identifying cases of intestinal taeniasis in a low-resource setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10358167PMC
http://dx.doi.org/10.1128/jcm.00282-23DOI Listing

Publication Analysis

Top Keywords

coag elisa
24
field coag
16
standard assay
12
laboratory evaluation
8
enzyme-linked immunosorbent
8
immunosorbent assay
8
northern peru
8
developed evaluated
8
field assay
8
evaluation phase
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!