The rapid development of machine learning has increased interest in the use of deep learning methods in medical research. Deep learning in the medical field is used in disease detection and classification problems in the clinical decision-making process. Large amounts of labeled datasets are often required to train deep neural networks; however, in the medical field, the lack of a sufficient number of images in datasets and the difficulties encountered during data collection are among the main problems. In this study, we propose MediNet, a new 10-class visual dataset consisting of Rontgen (X-ray), Computed Tomography (CT), Magnetic Resonance Imaging (MRI), Ultrasound, and Histopathological images such as calcaneal normal, calcaneal tumor, colon benign colon adenocarcinoma, brain normal, brain tumor, breast benign, breast malignant, chest normal, chest pneumonia. AlexNet, VGG19-BN, Inception V3, DenseNet 121, ResNet 101, EfficientNet B0, Nested-LSTM + CNN, and proposed RdiNet deep learning algorithms are used in the transfer learning for pre-training and classification application. Transfer learning aims to apply previously learned knowledge in a new task. Seven algorithms were trained with the MediNet dataset, and the models obtained from these algorithms, namely feature vectors, were recorded. Pre-training models were used for classification studies on chest X-ray images, diabetic retinopathy, and Covid-19 datasets with the transfer learning technique. In performance measurement, an accuracy of 94.84% was obtained in the traditional classification study for the InceptionV3 model in the classification study performed on the Chest X-Ray Images dataset, and the accuracy was increased 98.71% after the transfer learning technique was applied. In the Covid-19 dataset, the classification success of the DenseNet121 model before pre-trained was 88%, while the performance after the transfer application with MediNet was 92%. In the Diabetic retinopathy dataset, the classification success of the Nested-LSTM + CNN model before pre-trained was 79.35%, while the classification success was 81.52% after the transfer application with MediNet. The comparison of results obtained from experimental studies observed that the proposed method produced more successful results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10025796PMC
http://dx.doi.org/10.1007/s11042-023-14831-1DOI Listing

Publication Analysis

Top Keywords

transfer learning
20
deep learning
12
classification success
12
learning
9
medical field
8
classification
8
nested-lstm cnn
8
chest x-ray
8
x-ray images
8
diabetic retinopathy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!