Background: Left atrial appendage closure (LAAC) can be an alternative to oral anticoagulant therapy in patients with non-valvular atrial fibrillation, characterized by high risk of stroke (CHA2D2VASC ≥ two for men and CHA2D2VA2SC ≥ three for women) and high risk of bleeding (HASBLED = 3).

Case Summary: We describe three case reports in which an intracardiac echocardiography probe was used via the oesophageal route as an alternative to traditional transoesophageal echocardiography (TEE) or ICE methods to guide LAAC. Guiding the procedure via conventional TEE, even if feasible, could be difficult in these patients due to different causes: one patient was affected by Brugada syndrome while the other two patients reported oropharyngeal abnormalities. For these reasons, we performed an alternative use of the ICE probe to guide the entire LAAC procedure.

Discussion: Currently, LAAC is performed using intracardiac or transoesophageal echocardiography. This alternative use of ICE probe via oesophageal (ICE-TEE) is reported in previous studies that describe the feasibility of this technique both in excluding the presence of thrombus in left atrial appendage before cardioversion and in guiding percutaneous foramen ovale closure. Therefore, the ICE probe has been used as an intraoperative transoesophageal echocardiographic probe to repair congenital heart disease in infants or children with oropharyngeal abnormalities.This case series reports the first use of ICE-TEE to guide the entire LAAC procedure, guaranteeing the visualization of all echocardiographic views needed to perform it. The present case series highlights the potential of ICE-TEE to safely perform both pre-procedural and intraoperative evaluations in LAAC procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10285631PMC
http://dx.doi.org/10.1093/ehjcr/ytad261DOI Listing

Publication Analysis

Top Keywords

probe oesophageal
12
left atrial
12
atrial appendage
12
case series
12
ice probe
12
intracardiac echocardiography
8
echocardiography probe
8
appendage closure
8
high risk
8
transoesophageal echocardiography
8

Similar Publications

Objective: To assess the agreement of transpulmonary thermodilution (TPTD) and transpulmonary ultrasound dilution (TPUD) against direct measurement of main pulmonary artery flow with an ultrasound transit time flow probe (UTF) over a wide range of conditions in anesthetized cats. Additionally, the trending ability of TPTD, TPUD, and esophageal Doppler ultrasonography (EDU) was evaluated against UTF.

Methods: 12 purpose-bred cats were used.

View Article and Find Full Text PDF

Background/aims: Functional lumen imaging probe (FLIP) Panometry has demonstrated utility in the assessment of esophageal motility as a complement to existing methodologies like high-resolution manometry. However, as FLIP is typically performed with sedation during routine endoscopy, there is potential for impact of sedation agents on esophageal motility. We aim to examine the effects of conscious sedation with midazolam and fentanyl on FLIP Panometry metrics and classification.

View Article and Find Full Text PDF

Introduction: Cancer ranks as the second most prevalent cause of death worldwide, responsible for approximately 9.6 million deaths annually. Approximately one out of every six deaths is caused by cancer.

View Article and Find Full Text PDF

Background: Sperm-associated antigen 5 (SPAG5) is a mitotic spindle protein crucial for coordinating the separation of sister chromatids into daughter cells. Increasing evidence suggests that SPAG5 is overexpressed in various malignancies, functioning as an oncogene. However, research specifically examining SPAG5 in esophageal cancer remains limited.

View Article and Find Full Text PDF

Effectively interfering with endoplasmic reticulum (ER) function in tumor cells and simultaneously activating an anti-tumor immune microenvironment to attack the tumor cells are promising strategies for cancer treatment. However, precise ER-stress induction is still a huge challenge. In this study, we synthesized a near-infrared (NIR) probe, NIR-715, which induces tumor cell death and inhibits tumor growth without causing apparent side effects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!