A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical outcomes of vacuum-dehydrated amniotic membrane (Omnigen) mounted on contact lens (Omnilenz) in eyes with acute chemical eye injuries. | LitMetric

Background: Omnigen is a vacuum-dehydrated amniotic membrane transplant. It can be delivered to the eye pre-mounted on a special bandage contact lens (Omnilenz) that enables its application without the need for sutures or glue; the aim of this study is to evaluate the short-term clinical outcomes of Omnilenz-Omnigen complex in eyes with acute chemical injury (CEI).

Methods: A prospective interventional study included patients with different grades of acute CEI attending the casualty between July 2021 and November 2022. All patients received first aid measures followed by the application of Omnilenz-Omnigen within the first 2 days. Patients were followed up for at least 1 month. Primary outcomes include epithelial defect and limbal ischemia. Secondary outcomes include best-corrected visual acuity (BCVA) and tolerability.

Results: The study included 23 eyes of 21 patients with acute CEI mostly due to alcohol (34.8%). After the 1 application, the size of the epithelial defect showed a statistically significant reduction (p = 0.016) with improvement in BCVA (p < 0.001). Restoration of the limbal vascularity was obtained in 56.5% of the eyes. Repeated application of Omnilenz was required in 5 eyes (21.7%). The size of the epithelial defect was reduced after the second application (p = 0.504) with improved BCVA (p = 0.185). After 1 month, complete epithelial healing was achieved in all the eyes. Mild limbal ischemia persists in 3 (13%) of the eyes. Final BCVA showed statistically significant improvement (p < 0.001). None of the patients develops any serious complications.

Conclusion: Omnilenz proved to be easy to apply and well tolerated by patients, with promising clinical outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667437PMC
http://dx.doi.org/10.1007/s00417-023-06151-9DOI Listing

Publication Analysis

Top Keywords

clinical outcomes
12
epithelial defect
12
vacuum-dehydrated amniotic
8
amniotic membrane
8
contact lens
8
lens omnilenz
8
eyes acute
8
acute chemical
8
study included
8
acute cei
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!