AI Article Synopsis

  • The study explores the effectiveness of laser treatment for pilonidal sinus disease (PSD), highlighting its benefits over traditional surgical methods, such as less postoperative pain and quicker recovery times.
  • Involving 106 patients treated with a 1470-nm diode laser, the study compares outcomes between those treated with and without an endoscopic camera, finding no significant differences in pain, recovery, or complications.
  • Results indicate high patient satisfaction (99%) and an acceptable recurrence rate (11%), suggesting that laser treatment is a promising option for PSD, though more research on the use of endoscopic cameras is needed.

Article Abstract

Purpose: Nowadays, surgical treatment of pilonidal sinus disease (PSD) with novel techniques is a topic of interest since conventional methods are associated with longer return to daily life and higher complication and recurrence rates. Recently, use of laser as a minimally invasive approach has become popular in the surgical treatment of PSD. In this study, we analyze the short- and mid-term results after laser treatment and the effect of endoscopic camera use on outcomes.

Methods: A total of 106 patients with PSD who underwent laser treatment between November 2017 and September 2021 were included in this study. All patients were treated with a 1470-nm diode laser. Endoscopic camera was used in 73 patients and results of these were compared with those in whom camera was not used. Follow-up period was determined as a minimum of 1 year. Data were analyzed retrospectively.

Results: There were 80 (75%) male and 26 female patients. The median age was 26 (range 13-50) years. On the first postoperative day, 26 (26.5%) patients did not have any pain and 42(42.8%) patients reported low-grade pain. The mean time to return to daily life was 4.5 ± 5.5 (median 2, range 1-30) days. The complication rate was 10.4%. Eighty-six (87.8%) patients completely recovered and the mean complete recovery time was 27.4 ± 15.9 days. The patient satisfaction rate was 99.0%. The recurrence rate was 11.0%. Neither history of previous surgery nor abscess was associated with recurrence. Use of an endoscopic camera had no effect on postoperative pain, complete recovery, complications, patient satisfaction, and recurrence (p < 0.05).

Conclusion: Laser treatment for PSD is a promising approach with the advantages of less postoperative pain, early return to daily life, high patient satisfaction, and acceptable complication and recurrence rates. Nevertheless, further studies are needed to investigate the role of endoscopic camera use in this procedure since its possible advantages could not be clarified.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10151-023-02831-0DOI Listing

Publication Analysis

Top Keywords

endoscopic camera
16
laser treatment
12
short- mid-term
8
diode laser
8
treatment pilonidal
8
pilonidal sinus
8
sinus disease
8
surgical treatment
8
return daily
8
daily life
8

Similar Publications

Alcohol-based fuels have shown high compatibility with spark-ignition (SI) engines, which require improvements in fuel efficiency and emissions reduction to meet modern environmental standards. While extensive research has been conducted on ethanol and other lower-order alcohols, there has been comparatively limited investigation into higher-order alcohols like butanol and pentanol as fuel alternatives. Previous studies on pentanol-gasoline blends in SI engines have demonstrated improved engine performance and reduced emissions.

View Article and Find Full Text PDF

Background: Single port robotic platform offers articulation and 360° camera rotation for anorectal tumour excision in a narrow pelvic space. This study assesses the clinical usefulness and outcomes of SP robotic transanal surgery.

Methods: Nine patients who underwent transanal excision using the SP robotic platform were included.

View Article and Find Full Text PDF

As musculoskeletal injuries in gastroenterologists related to the performance of endoscopic procedures are on the rise, solutions and new approaches are needed to prevent these undesired outcomes. In our study, we evaluated an approach to ergonomic challenges in the form of a belt-like endoscope holder designed to redistribute the weight of the endoscope across the whole body of the practitioner. The aim of the study was to determine how the use of this holder affected the body posture of practitioners during endoscopy.

View Article and Find Full Text PDF

Rapid diagnosis of cerebrospinal fluid (CSF) leaks is critical as endoscopic endonasal skull base surgery gains global prominence. Current clinical methods such as endoscopic examination with and without intrathecal injection of fluorescent dye are invasive and rely on subjective judgment by physicians, highlighting the clinical need for label-free point-of-care (POC). However, a viable solution remains undeveloped due to the molecular complexity of CSF rhinorrhea mixed with nasal discharge and the scarcity of specific biomarkers, delaying sensor development.

View Article and Find Full Text PDF

Colonoscopies are vital procedures allowing diagnosis of colorectal cancer and other gastrointestinal diseases. However, excessive forces may be applied to the colon during navigation. This can cause bleeding, especially in patients presenting inflammatory bowel diseases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!