SERS-active substrates using DVD-R coated in silver thin films: A preliminary study for detection of commercial glyphosate.

Spectrochim Acta A Mol Biomol Spectrosc

Universidade do Vale do Paraíba, Instituto de Pesquisa e Desenvolvimento, Laboratório de, Nanossensores, Avenida Shishima Hifumi, 2911, Urbanova - 12244-000, São José dos Campos, Brazil. Electronic address:

Published: December 2023

Glyphosate (GLP) is the herbicide with the highest level of global commercialization and historical use. Even though numerous studies have found this substance to be harmless, current research demonstrates that GLP might affect human health. For this reason, researcher efforts are concentrating on alternatives for analytical quantification, such as Surface Enhanced Raman Spectroscopy (SERS). In this work, a DVD-R@AgNPs SERS substrate was produced by the Cathodic Cage Plasma Deposition (CCPD) technique, which allowed a thin film layer deposition of silver nanoparticles (AgNPs) on the PC grating structure from Digital Video/Versatile Disc Recordable (DVD-R). Scanning Electron Microscopy with energy-dispersive X-ray spectroscopy was used to characterize the substrate and chemical changes on the surface after AgNPs deposition. The DVD-R@AgNPs substrate was used to detect standard crystal violet (CV), GLP, and Roundup GLP (GLP-RU) using Raman Spectroscopy. The CV was used as a control sample for SERS measurement, allowing the calculation of the substrate enhancement factor, which was in the order of ∼ 10. To evaluate the efficiency of the SERS substrate, the limit of detection was calculated and showed values of ∼ 10 mol/L for CV, 10 and 10 mol/L for GLP, and 10 mol/L for GLP-RU. Thus, the DVD-R@AgNPs SERS sensor is a low-cost substrate that analyzes traces of pesticides such as commercial GLP, demonstrating high SERS sensitivities and many applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2023.123017DOI Listing

Publication Analysis

Top Keywords

raman spectroscopy
8
dvd-r@agnps sers
8
sers substrate
8
glp
6
sers
6
substrate
6
sers-active substrates
4
substrates dvd-r
4
dvd-r coated
4
coated silver
4

Similar Publications

The utilization of single crystals is exponentially growing in optoelectronic devices due to their exceptional benefits, including high phase purity and the absence of grain boundaries. However, achieving single crystals with a porous structure poses significant challenges. In this study, we present a method for fabricating porous single crystals (porous-SC) of CsAgBiBr and related halide double perovskites using an infrared-assisted spin coating technique.

View Article and Find Full Text PDF

An ultrafast algorithm for ultrafast time-resolved coherent Raman spectroscopy.

Commun Chem

January 2025

Energy & Materials Transition, Netherlands Organization for Applied Scientific Research (TNO), Urmonderbaan 22, Geleen, 6167RD, The Netherlands.

Time-resolved coherent Raman spectroscopy (CRS) is a powerful non-linear optical technique for quantitative, in-situ analysis of chemically reacting flows, offering unparalleled accuracy and exceptional spatiotemporal resolution. Its application to large polyatomic molecules, crucial for understanding reaction dynamics, has thus far been limited by the complexity of their rotational-vibrational Raman spectra. Progress in developing comprehensive spectral codes for these molecules, a longstanding goal, has been hindered by prohibitively long computation times required for their spectral synthesis.

View Article and Find Full Text PDF

Prostate cancer is a disease which poses an interesting clinical question: Should it be treated? Only a small subset of prostate cancers are aggressive and require removal and treatment to prevent metastatic spread. However, conventional diagnostics remain challenged to risk-stratify such patients; hence, new methods of approach to biomolecularly sub-classify the disease are needed. Here we use an unsupervised self-organising map approach to analyse live-cell Raman spectroscopy data obtained from prostate cell-lines; our aim is to exemplify this method to sub-stratify, at the single-cell-level, the cancer disease state using high-dimensional datasets with minimal preprocessing.

View Article and Find Full Text PDF

This study used Raman and near-infrared (NIR) spectroscopy to monitor small real-time changes in powder blends and tablets in low-dose pharmaceutical formulations. The research aims to enhance process analytical technology (PAT) in pharmaceutical manufacturing, ensuring high-quality and uniform products with applications to produce drugs with narrow therapeutic indices (NTI). The study utilizes Raman and NIR spatially resolved spectroscopy (SRS) techniques to monitor a moderate cohesive material's active pharmaceutical ingredient (API) concentrations during manufacturing.

View Article and Find Full Text PDF

The accumulation of disposable face masks (DFMs) has become a significant threat to the environment due to extensive use during the COVID-19 pandemic. In this research, we investigated the degradation of DFMs after their disposal in landfills. We replicated the potential degradation process of DFMs, including exposure to sunlight before subjecting them to synthetic landfill leachate (LL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!