Throughout the entire coronavirus disease 19 (COVID-19) pandemic, there were disruptions in the supply chain of test materials around the world, primarily in poor- and middle-income countries. The use of 3D prints is an alternative to address swab supply shortages. In this study, the feasibility of the clinical use of 3D-printed swabs for oropharyngeal and nasopharyngeal sampling for the detection of SARS-CoV-2 infection was evaluated. For that purpose, paired samples with the 3D printed and the control swabs were taken from 42 adult patients and 10 pediatric patients, and the results obtained in the detection of SARS-CoV-2 by reverse transcription and quantitative polymerase chain reaction (RT-qPCR) were compared. Additionally, in those cases where the result was positive for SARS-CoV-2, the viral load was calculated by means of a mathematical algorithm proposed by us. For both adults and children, satisfactory results were obtained in the detection of SARS-CoV-2 by RT-qPCR; no significant differences were found in the quantification cycle values between the 3D-printed swab samples and the control samples. Furthermore, we corroborated that the 3D-printed swabs caused less discomfort and pain at the time of sampling. In conclusion, this study shows the feasibility of routinely using 3D-printed swabs for both adults and children. In this way, it is possible to maintain local and cheaper consumption along with fewer distribution difficulties.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10281960 | PMC |
http://dx.doi.org/10.1093/biomethods/bpad009 | DOI Listing |
BMC Oral Health
October 2024
Department of Oral and Craniofacial Sciences, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, 50603, Malaysia.
Background: The aim of this study was to investigate the microbiome shift of denture biofilm formation, the incidence of Candida and changes of salivary inflammatory markers following insertion of 3-dimensional printed PMMA denture.
Methods: This was a pilot study of 6 patients provided with 3D printed (test group) or conventionally heat-cured (control group) removable partial acrylic dentures followed up for 6 weeks. 3 denture swabs were collected at week 1, 3 and 6; and saliva samples were collected at baseline, week 1, 3 and 6 following denture insertion.
Mem Inst Oswaldo Cruz
October 2024
Conselho Nacional de Desenvolvimento Científico e Tecnológico, Instituto Nacional de Ciência e Tecnologia em Entomologia Molecular, Rio de Janeiro, RJ, Brasil.
Sci Rep
July 2024
Department of Metabolism, Digestion and Reproduction, Faculty of Medicine, Imperial College London, London, UK.
Investigating the gut microbiome and metabolome frequently requires faecal samples, which can be difficult to obtain. Previous studies have shown that rectal swabs are comparable to faecal samples for analysing gut microbiota composition and key metabolites. In this study, 3D printed rectal swabs were compared with conventional flocked swabs and faecal samples, due to the potential advantages 3D printing as a technique offers for swab production and development.
View Article and Find Full Text PDFGMS Hyg Infect Control
February 2024
Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Leipzig, Germany.
Errors in laboratory diagnostics of viral infections primarily occur during the preanalytical phase, which is especially observed in sample collection. Hitherto, no efforts have been made to optimize oropharyngeal smears. An accurate method to analyze the necessary conditions for a valid oropharyngeal smear test is required, especially to avoid false negative results, which can lead to promotion of the spread of viruses such as SARS-CoV-2.
View Article and Find Full Text PDFMikrochim Acta
February 2024
Department of Analytical Chemistry, ECsens, University of Granada, Campus Fuentenueva, Granada, Spain.
Salivary pH serves as a valuable and useful diagnostic marker for periodontal disease, as it not only plays a critical role in disease prevention but also in its development. Typically, saliva sampling is collected by draining and spitting it into collection tubes or using swabs. In this study, we have developed a Point-of-Care (POC) device for in situ determination of oral pH without the need for complex instruments, relying solely on a smartphone as the detection device.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!