AI Article Synopsis

  • Traditional methods for measuring protein biomarkers in blood are complicated and time-consuming, requiring extensive incubation and washing steps.
  • A new wearable patch has been developed for real-time detection of C-reactive protein (CRP) in sweat, addressing variations in sweat composition and allowing for easier point-of-care monitoring.
  • This patch combines sweat extraction, microfluidic technology, and a graphene-based sensor to accurately measure CRP levels, showing strong correlations with serum CRP levels in patients with chronic conditions.

Article Abstract

The quantification of protein biomarkers in blood at picomolar-level sensitivity requires labour-intensive incubation and washing steps. Sensing proteins in sweat, which would allow for point-of-care monitoring, is hindered by the typically large interpersonal and intrapersonal variations in its composition. Here we report the design and performance of a wearable and wireless patch for the real-time electrochemical detection of the inflammatory biomarker C-reactive (CRP) protein in sweat. The device integrates iontophoretic sweat extraction, microfluidic channels for sweat sampling and for reagent routing and replacement, and a graphene-based sensor array for quantifying CRP (via an electrode functionalized with anti-CRP capture antibodies-conjugated gold nanoparticles), ionic strength, pH and temperature for the real-time calibration of the CRP sensor. In patients with chronic obstructive pulmonary disease, with active or past infections or who had heart failure, the elevated concentrations of CRP measured via the patch correlated well with the protein's levels in serum. Wearable biosensors for the real-time sensitive analysis of inflammatory proteins in sweat may facilitate the management of chronic diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10592261PMC
http://dx.doi.org/10.1038/s41551-023-01059-5DOI Listing

Publication Analysis

Top Keywords

wireless patch
8
protein sweat
8
proteins sweat
8
sweat
6
patch monitoring
4
monitoring c-reactive
4
c-reactive protein
4
sweat quantification
4
quantification protein
4
protein biomarkers
4

Similar Publications

This paper presents novel MIMO microstrip patch antennas with dimensions of 40 × 80 × 1.6 mm³ incorporating a decoupling and pattern correction structure (DPCS) designed to mitigate mutual coupling and radiation pattern distortion, operating within 3.6-3.

View Article and Find Full Text PDF

Vital signs such as heart rate (HR) and respiration rate (RR) are essential physiological parameters that are routinely used to monitor human health and bodily functions. They can be continuously monitored through contact or contactless measurements performed in the home or a hospital. In this study, a contactless Doppler radar W-band sensing system was used for short-range, contactless vital sign estimation.

View Article and Find Full Text PDF

Intelligent Microneedles Patch with Wireless Self-Sensing and Anti-Infective Actions.

Small

December 2024

Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, 130012, China.

Traditional microneedle (MN) technology offers unique advantages in treating wound infections; however, its single-function design lacks the capability for real-time monitoring of wound conditions, often resulting in uncontrolled drug release. Herein, an anti-infective and intelligent MN patch (SP-CSMN) integrating three functional modules is developed, including temperature monitoring, Bluetooth wireless communication, and responsive drug release. The patch employed chitosan (CS) as a porous substrate, filled with temperature-sensitive poly(N-isopropylacrylamide) (PNIPAM) to encapsulate and release the antibiotic rifampicin.

View Article and Find Full Text PDF

Design and Fabrication of a Patch Antenna for 5G Wireless Communications from a Low-Permittivity LiAlSiO-Based Ceramic.

ACS Appl Mater Interfaces

December 2024

Guangxi Universities Key Laboratory of Non-ferrous Metal Oxide Electronic Functional Materials and Devices, College of Material Science and Engineering, Guilin University of Technology, Guilin 541004, China.

A microwave dielectric ceramic based on lithium aluminum silicate (LiAlSiO) with ultralow permittivity was synthesized using the traditional solid-state reaction technique, and its dielectric characteristics at microwave frequencies are presented. The nominal LiAlSiO ceramic exhibited a relative permittivity of 3.95.

View Article and Find Full Text PDF

Ammonium level in body fluids serves as one of the critical biomarkers for healthcare, especially those relative to liver diseases. The continuous and real-time monitoring in both invasive and non-invasive manners is highly desired, while the ammonium concentrations vary largely in different body fluids. Besides, the sensing reliability based on ion-selective biosensors can be significantly interfered by potassium ions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!