Velocity field distribution control in antisolvent flow realizing highly stable and efficient perovskite nanocrystals.

J Colloid Interface Sci

Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, PR China.

Published: November 2023

Achieving highly stable and efficient perovskite nanocrystals (NCs) without applying functional additives or encapsulation, particularly sustaining the stability in ultra-dilute solution, is still a formidable challenge. Here, we show the FAPbI perovskite NCs with achieved ∼100 % photoluminescence quantum yield (PLQY) and low defect density (∼0.2 cm per NCs), which is obtained by controlling the velocity field distribution of antisolvent flow in ligand-assisted reprecipitation process. The NCs show incredible reproducibility with narrow deviation of PLQY and linewidth between batch by batch, as well as remarkable stability of maintaining over 80 % PLQY, either in an ultra-diluted solution (9.3 × 10 mg/mL), or storing in ambient condition after 90 days with concentration of 0.09 mg/mL. The results in this work demonstrate the interplay of fluid mechanics and crystallization kinetics of perovskite, which pioneers a novel and unprecedent understanding for improving the stability of perovskite NCs for efficient quantum light source.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcis.2023.06.114DOI Listing

Publication Analysis

Top Keywords

velocity field
8
field distribution
8
antisolvent flow
8
highly stable
8
stable efficient
8
efficient perovskite
8
perovskite nanocrystals
8
perovskite ncs
8
perovskite
5
ncs
5

Similar Publications

The effect of atomic vibration on thermal transport in diatomic semiconductors investigated molecular dynamics.

Nanoscale

January 2025

Laboratory for Multiscale Mechanics and Medical Science, SV LAB, School of Aerospace, Xi'an Jiaotong University, Xi'an 710049, China.

Based on the molecular dynamics (AIMD), the temperature and velocity statistics of diatomic semiconductors were proposed to be classified by atomic species. The phase differences resulting from lattice vibrations of different atoms indicated the presence of anharmonicity at finite atomic temperatures. To further explore the electronic properties, the effect of temperature on electrostatic potential field vibrations in semiconductors was studied, and the concept of electrostatic potential oscillation (EPO) at finite atomic temperature was introduced.

View Article and Find Full Text PDF

25 thousand years ago, the European Alps were covered by the kilometre-thick Alpine Ice Field. Numerical modelling of this glaciation has been challenged by model-data disagreements, including overestimations of ice thickness. We tackle this issue by applying the Instructed Glacier Model, a three-dimensional model enhanced with physics-informed machine learning.

View Article and Find Full Text PDF

Context: Concussion causes physiological disruptions, including disruptions to the vestibular and visual systems, which can cause dizziness, imbalance, and blurry vision. The vestibular ocular reflex functions to maintain a stable visual field, which can be measured using the gaze stability test (GST).

Design: This preliminary study used retrospective chart review to examine changes in GST performance and asymmetry in a sample of 117 youth athletes with concussion (mean age = 14.

View Article and Find Full Text PDF

The design of the flow field structure for bipolar plates significantly influences the output performance of proton exchange membrane fuel cells (PEMFCs). Adding baffles in the flow channels can enhance the transportation of reactants and electrochemical performance of the PEMFCs. In this study, three types of baffles with different shapes and sizes were designed.

View Article and Find Full Text PDF

Objectives: To promote standardization and feasible measurements of gait speed across the field, we developed a device that used light detection and ranging (LiDAR) technology to measure gait speed from a standing-start testing procedure conducted on a 4-m total walkway. We compared this automated (LiDAR-based) standing-start 4-m gait speed test (AS-4MG) with automated and manual (stopwatch-based) dynamic-start 4-m gait speed tests (AD-4MG and MD-4MG, respectively) on between-method agreement, measurement repeatability, and predictive validity with functional outcomes.

Methods: A sample of 48 community-dwelling adults (mean [SD], 69 [9] years) participated in this method comparison study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!