The conditions of temperature, pressure, and saturation in which respiratory gas volumes are expressed [standard temperature and pressure, dry (STPD), ambient temperature and pressure, saturated (ATPS), or body temperature and pressure, saturated (BTPS)] are physiologically relevant, but often ignored or unknown in clinical practice. In this study, we aimed to investigate whether and at which extent the gas volume corrections, either in natural or artificial lung, may alter key respiratory and metabolic variables and the possible clinical consequences. We primarily referred to the effects of gas volume corrections on three physiological variables: physiological dead space, venous admixture, and total CO production (V̇co) during extracorporeal support. We used three physiological models in which calculations of these variables have been performed with and without correction of gas volumes, both in a theoretical model and in 448 patients. The lack of gas volume correction leads to an error in the computation of physiological dead space fraction between 0.05 and 0.15, both in the theoretical model and in the patient population. The venous admixture was minimally affected by the absence of correction (0.01-0.04 error). During extracorporeal support, if the V̇co of natural and membrane lung is expressed in different conditions, potentially large errors (0%-18.4%) may occur in the computation of total V̇co (V̇co = V̇co + V̇co). This may lead to inappropriate settings of mechanical ventilation with higher plateau pressure. As the dead space and the CO sharing between natural and artificial lung are relevant both as prognostic index and as a guide for appropriate mechanical ventilation, their inappropriate computation may lead to erroneous categorization of the patients and inappropriate mechanical treatment. Gas volume conditions are often ignored or unknown in the clinical practice. However, they could have relevance for the calculation of some key variables in ICU setting. This study shows that gas volume corrections are mostly relevant when assessing CO clearance, both in mechanical ventilation and during extracorporeal support, whereas irrelevant for oxygenation assessment of patients. Knowing when the appropriate corrections are needed allows to better understand patients' clinical conditions and to tailor the treatment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10390049 | PMC |
http://dx.doi.org/10.1152/japplphysiol.00225.2023 | DOI Listing |
Small
January 2025
Department of Physics, Malaviya National Institute of Technology Jaipur, Rajasthan, 302017, India.
Increasing attention to sustainability and cost-effectiveness in energy storage sector has catalyzed the rise of rechargeable Zinc-ion batteries (ZIBs). However, finding replacement for limited cycle-life Zn-anode is a major challenge. Molybdenum disulfide (MoS), an insertion-type 2D layered material, has shown promising characteristics as a ZIB anode.
View Article and Find Full Text PDFZhonghua Wei Zhong Bing Ji Jiu Yi Xue
December 2024
Department of Public Utilities Development, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, Henan, China.
Objective: To explore the effects of veno-venous extra corporeal carbon dioxide removal (V-V ECCOR) on local mechanical power and gas distribution in the lungs of patients with mild to moderate acute respiratory distress syndrome (ARDS) receiving non-invasive ventilation.
Methods: Retrospective research methods were conducted. Sixty patients with mild to moderate ARDS complicated with renal insufficiency who were transferred to the respiratory intensive care unit (RICU) through the 96195 platform critical care transport green channel from January 2018 to January 2020 at the collaborative hospitals of Henan Provincial People's Hospital were enrolled.
Cardiol Young
January 2025
Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
Objective: Syncope is common among pediatric patients and is rarely pathologic. The mechanisms for symptoms during exercise are less well understood than the resting mechanisms. Additionally, inert gas rebreathing analysis, a non-invasive examination of haemodynamics including cardiac output, has not previously been studied in youth with neurocardiogenic syncope.
View Article and Find Full Text PDFSci Rep
January 2025
College of Civil Engineering, Department of Bridge Engineering, Tongji University, Shanghai, 200092, China.
Addressing environmental challenges such as pollution and resource depletion requires innovative industrial and municipal waste management approaches. Cement production, a significant contributor to greenhouse gas emissions, highlights the need for eco-friendly building materials to combat global warming and promote sustainability. This study evaluates the simultaneous use of Sugarcane Bagasse Ash (SCBA) and Stone Dust (SD) as partial replacements by volume for cement and sand, respectively, at varying ratios in eco-strength concrete mixes designed for 28 MPa (ES-28) and 34 MPa (ES-34), emphasizing their economic and environmental benefits.
View Article and Find Full Text PDFSurg Endosc
January 2025
Division of Transplant Surgery, Department of Surgery, Hume- Lee Transplant Center, Virginia Commonwealth University School of Medicine, Richmond, VA, USA.
Background: Robotic living donor hepatectomy offers potential advantages but has been limited to high-volume centers, primarily in Asia and the Middle East. We report our experience establishing a robotic living donor right hepatectomy program in a U.S.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!