Review of oxygen-enhanced lung mri: Pulse sequences for image acquisition and T measurement.

Med Phys

Department of Electrical and Electronic Engineering, Faculty of Science and Engineering, University of Nottingham Ningbo China, Ningbo, China.

Published: October 2023

Oxygen-enhanced MR imaging (OE-MRI) is a special proton imaging technique that can be performed without modifying the scanner hardware. Many fundamental studies have been conducted following the initial reporting of this technique in 1996, illustrating the high potential for its clinical application. This review aims to summarise and analyse current pulse sequences and T measurement methods for OE-MRI, including fundamental theories, existing pulse sequences applied to OE-MRI acquisition and T mapping. Wash-in and wash-out time identify lung function and are sensitive to ventilation; thus, dynamic OE-MRI is also discussed in this review. We compare OE-MRI with the primary competitive technique, hyperpolarised gas MRI. Finally, an overview of lower-field applications of OE-MRI is highlighted, as relatively recent publications demonstrated positive results. Lower-field OE-MRI, which is lower than 1.5 T, could be an alternative modality for detecting lung diseases. This educational review is aimed at researchers who want a quick summary of the steps needed to perform pulmonary OE-MRI with a particular focus on sequence design, settings, and quantification methods.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.16553DOI Listing

Publication Analysis

Top Keywords

pulse sequences
12
oe-mri
8
review
4
review oxygen-enhanced
4
oxygen-enhanced lung
4
lung mri
4
mri pulse
4
sequences image
4
image acquisition
4
acquisition measurement
4

Similar Publications

Humic substances modulate bacterial communities and mitigate adverse effects of temperature stress in coral reef organisms.

J Appl Microbiol

January 2025

Centre for Environmental and Marine Studies (CESAM) and Department of Biology, University of Aveiro, Aveiro, Portugal.

Aims: In the present study, we tested if terrestrially-derived humic substances (HS) could mitigate the adverse effects of elevated temperature and UVB radiation on the bacterial communities of two hard corals (Montipora digitata and Montipora capricornis), one soft coral (Sarcophyton glaucum), sediment and water. We also examined the impact of temperature, UVB radiation and HS supplementation on coral photosynthetic activity, a proxy for coral bleaching.

Methods And Results: We performed a multifactorial experiment using a randomized-controlled microcosm setup.

View Article and Find Full Text PDF

The femtosecond dynamics of energy transfer from light-excited spirilloxanthin (Spx) to bacteriochlorophyll (BChl) a in the reaction centers (RCs) of purple photosynthetic bacteria Rhodospirillum rubrum was studied. According to crio-electron microscopy data, Spx is located near accessory BChl a in the B-branch of cofactors. Spx was excited by 25 fs laser pulses at 490 nm, and difference absorption spectra were recorded in the range 500-700 nm.

View Article and Find Full Text PDF

Nexus: A versatile console for advanced low-field MRI.

Magn Reson Med

January 2025

Department 8.1 - Biomedical Magnetic Resonance, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.

Purpose: To develop a low-cost, high-performance, versatile, open-source console for low-field MRI applications that can integrate a multitude of different auxiliary sensors.

Methods: A new MR console was realized with four transmission and eight reception channels. The interface cards for signal transmission and reception are installed in PCI Express slots, allowing console integration in a commercial PC rack.

View Article and Find Full Text PDF

Pulse approach: a physics-guided machine learning model for thermal analysis in laser-based powder bed fusion of metals.

Prog Addit Manuf

July 2024

Empa Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland.

Fast and accurate representation of heat transfer in laser powder-bed fusion of metals (PBF-LB/M) is essential for thermo-mechanical analyses. As an example, it benefits the detection of thermal hotspots at the design stage. While traditional physics-based numerical approaches such as the finite element (FE) method are applicable to a wide variety of problems, they are computationally too expensive for PBF-LB/M due to the space- and time-discretization requirements.

View Article and Find Full Text PDF

In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!