Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Image-based tumor dosimetry after radionuclide therapy, using the isotope Lu, finds application e.g., for tumor-to-organ dose comparison and for dose response evaluation. When the tumor extent is not much larger than the image resolution, and when Lu is found in nearby organs or other tumors, an accurate determination of tumor dose is particularly challenging. Here a quantitative evaluation of three different methods for determining the Lu activity concentration in a phantom is performed, and the dependence on a variety of parameters is described. The phantom (NEMA IEC body phantom) has spheres of different size in a background volume, and sphere-to-background Lu activity concentration ratios of infinity, 9.5, 5.0 and 2.7 are applied. The methods are simple to implement and well-known from the literature. They are based on (1) a large VOI encompassing the whole sphere, without background activity and with volume information from other sources, (2) a small VOI located in the sphere center, and (3) a VOI consisting of voxels with voxel value above a certain percentage of the maximum voxel value.
Results: The determined activity concentration varies significantly with sphere size, sphere-to-background ratio, SPECT reconstruction method and method for determining the concentration. Based on the phantom study, criteria are identified under which the activity concentration can be determined with a maximal error of 40% even in the presence of background activity.
Conclusions: Tumor dosimetry is feasible in the presence of background activity using the above-mentioned methods, provided appropriate SPECT reconstructions are applied and tumors are selected for dosimetry analysis according to the following criteria for the three methods: (1) solitary tumor with diameter > 15 mm, (2) tumor diameter > 30 mm and tumor-to-background ratio > 2, and (3) tumor diameter > 30 mm and tumor-to-background ratio > 3.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10284754 | PMC |
http://dx.doi.org/10.1186/s40658-023-00561-8 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!