Purpose: Both flexible intramedullary nails (FINs) and plate osteosynthesis are commonly used for the treatment of femoral shaft fractures in pediatric patients. The purpose of this study is to determine the refracture rate after hardware removal in pediatric femur fractures.
Methods: This is a retrospective cohort study that utilized the Pediatric Health Information System database to determine the number of pediatric patients ages 4 to 10 who underwent surgical fixation of a femur fracture and subsequent hardware removal between the years 2015 and 2019. All patients had a minimum of a 2-year follow-up to assess for refracture. Patients with metabolic bone disease, neuromuscular conditions, bone fragility disorders, nutritional deficiencies, and pathologic fractures were excluded.
Results: Of the total, 2805 pediatric patients with 2881 femoral shaft fractures who underwent FIN (48.4%), plate fixation (36.1%), splinting/casting (14.9%), or external fixation (0.6%) were included. The mean age of patients with index fracture was 7.2 years (SD, 2.1) and 69% were males. Eight hundred eighty patients (60%) in the FIN group had their hardware removed compared with 693 patients (68%) in the plate fixation group ( P = 0.07), at an average of 287 ± 191 days versus 320 ± 203 days ( P = 0.03). Refracture occurred in 13 patients (1.5%) who had their hardware retained and in 21 patients (1.4%) who had their hardware removed ( P = 0.732). Among 65% of patients who underwent hardware removal, refracture occurred in 7 patients with FIN (0.8%) and 14 patients with plate fixation (2.2%) ( P = 0.04). Refracture occurred within 365 days from hardware removal in 1 patient with FIN (0.1%) and 7 patients with plate fixation (1%) ( P = 0.01). In logistic regression, patients with FIN fixation had lower odds of refracture after hardware removal compared with plate fixation (adjusted odds ratio: 0.39; 95% CI: 0.15-0.97). Age and payor status did not reach statistical significance in multivariate analysis.
Conclusions: The rate of refracture after hardware removal for pediatric patients with a femoral shaft fracture was similar between patients with hardware retained and removal. However, patients with FIN had a lower rate of refracture AFTER hardware removal compared with plate fixation. This information can be helpful for advising families regarding the risks of refracture after hardware removal.
Level Of Evidence: Level IV-retrospective cohort study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BPO.0000000000002454 | DOI Listing |
J Clin Orthop Trauma
March 2025
Department of Orthopaedic Surgery, Mercy St. Vincent Medical Center, 2213 Cherry St., Toledo, OH, 43608, USA.
Background: Gravid females with pelvic fractures are rarely encountered by the orthopaedic trauma surgeon. The initial injury can be detrimental to the pregnant patient, but an unnecessary "second hit" from surgery could also contribute to the outcome of the fetus. Understanding the surgical risks for this unique patient population requires knowledge about the negative effects of anesthesia, surgical exposures, and radiation.
View Article and Find Full Text PDFJ Foot Ankle Surg
January 2025
Department of Trauma and Orthopaedic Surgery, Tallaght University Hospital, Dublin, Ireland.
First metatarsophalangeal joint (MTPJ) fusion an effective surgical intervention for conditions such as hallux valgus and hallux rigidus. This systematic review and meta-analysis aims to compare safety and efficacy of crossed screws versus plating supplemented with an interfragmentary screw. A literature search of the Scopus, Embase, Web of Science, and MEDLINE databases was performed to identify all studies directly comparing the two techniques.
View Article and Find Full Text PDFInjury
January 2025
Department of Surgery, The Trauma and Orthopaedic Research Unit, The Canberra Hospital, Garran, Australian Capital Territory, Australia.
Background: Unstable posterior pelvic-ring fractures are rare and difficult to manage. There are many injury patterns, they are associated with high morbidity and mortality, and optimal surgical management remains contentions. This study aims to compare outcomes and complications for different surgical management of these injuries.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Department of Surgery, Haaglanden Medical Center, The Hague, The Netherlands.
Purpose: Guidelines for treatment of medium-sized posterior fragments in trimalleolar fractures are scarce and show varying advice. Recent trials comparing fixation and no fixation of posterior fragments, show no difference in outcomes one year postoperatively. This study compares functional outcome and development of osteoarthritis in patients with fixation of a posterior malleolar fracture to patients without fixation of the posterior malleolus fracture.
View Article and Find Full Text PDFGeorgian Med News
November 2024
Levan Samkharauli National Forensics Bureau, Tbilisi, Georgia.
Aim Of Study: The pathological examination is one of the longest in the list of medical tests. Most of this time is spent on preparation for the slide. In addition, part of the chemical reagents needed for processing is not safe for the environment and the personal working in the laboratory.