The co-located and concurrent measurement of both muscular neural activity and muscular deformation is considered necessary in many applications, such as medical robotics, assistive exoskeletons and muscle function evaluations. Nevertheless, conventional muscle-related signal perception systems either detect only one of these modalities, or are made with rigid and bulky components that cannot provide conformal and flexible interface. Herein, a flexible, easy-to-fabricate, bimodal muscular activity sensing device, which collects neural and mechanical signal at the same muscle location, is reported. The sensing patch includes a screen-printed sEMG sensor, and a pressure-based muscular deformation sensor (PMD sensor) based on a highly sensitive, co-planar iontronic pressure sensing unit. Both sensors are integrated on a super-thin (25 μm) substrate. The sEMG sensor shows a high signal-to-noise ratio of 37.1 dB, and the PMD sensor sensor exhibits a high sensitivity of 70.9 kPa . The responses of the sensor to three types of muscle activities (isotonic, isometric, and passive stretching) were analyzed and validated by ultrasound imaging. Bimodal signals during dynamic walking experiments with different level-ground walking speeds were also investigated. The application of the bimodal sensor was verified in gait phase estimation, and results show that the assembly of both modalities significantly reduce (p < 0.05) the average estimation error across all subjects and all walking speeds to 3.82%. Demonstrations show the potential of this sensing device for informative evaluation of muscular activities, and its abilities in human-robot interaction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TBME.2023.3287729 | DOI Listing |
J Mol Model
January 2025
Escuela Superior de Física y Matemáticas, IPN S/N, Edificio 9 de la Unidad Profesional "Adolfo López Mateos", Col. Lindavista, Alc. Gustavo A. Madero, 07738, Mexico City, Mexico.
Context: "Nanostructure of graphene-reinforced with polymethyl methacrylate" (PMMA-G), and vice versa, is investigated using its molecular structure, in the present work. The PMMA-G nanostructure was constructed by bonding PMMA with graphene nanosheet in a sense to get three different configurations. Each configuration consisted of polymeric structures with three degrees of polymerization (such as monomers, dimers, and trimers polymers, respectively).
View Article and Find Full Text PDFNano Lett
January 2025
Department of Electrical and Computer Engineering, Northwestern University, Evanston, Illinois 60208, United States.
Metasurfaces supporting narrowband resonances are of significant interest in photonics for molecular sensing, quantum light source engineering, and nonlinear photonics. However, many device architectures rely on large refractive index dielectric materials and lengthy fabrication processes. In this work, we demonstrate quasi-bound states in the continuum (quasi-BICs) using a polymer metasurface exhibiting experimental quality factors of 305 at visible wavelengths.
View Article and Find Full Text PDFAnal Methods
September 2020
College of Life Sciences, Fujian Normal University, Fuzhou 350117, Fujian, China.
An innovative magnetic immunoassay was developed for the voltammetric detection of carbohydrate antigen-125 (CA-125) on a home-made microfluidic device including a multisyringe pump, selection valve and magneto-controlled detection cell. Two kinds of biofunctionalized nanostructures including anti-CA-125 capture antibody-conjugated magnetic beads and anti-CA-125 detection antibody-labeled silver-polypyrrole (Ag-PPy) nanohybrids were utilized for a sandwiched immunoreaction in the presence of CA-125. With the help of an external magnet, the formed magnetic immunocomplexes were attached to the sensing interface to activate the electrical contact between Ag-PPy nanohybrids and the base electrode, thus resulting in the switching on of the sensor circuit for the generation of voltammetric signals thanks to electroactive Ag-PPy nanohybrids.
View Article and Find Full Text PDFAnal Methods
November 2017
Materials Science Centre, Indian Institute of Technology, Kharagpur-721302, India.
Functionalized polymer membrane electrodes based multichannel sensor is used as an electronic tongue to monitor the drinking water (DW) quality simply by measuring the surface electric potential with respect to Ag/AgCl reference electrode in 1 mM aqueous KCl. Changes of minute concentration of dissolved minerals greatly affected the surface potential of the sensor. The three-channel sensor device (electronic tongue) is made by using three different functionalized polymer membrane electrodes, namely, phosphorylated hexadecyl trimethyl ammonium chloride modified polyvinyl alcohol-polyacrylic acid membrane; phosphorylated and crosslinked polyvinyl--ethylene membrane; phosphorylated and crosslinked polyvinyl alcohol membrane, as working electrodes and a Ag/AgCl reference electrode.
View Article and Find Full Text PDFLight Sci Appl
January 2025
National and Local United Engineering Laboratory of Flat Panel Display Technology, College of Physics and Information Engineering, Fuzhou University, 350108, Fuzhou, China.
Multifunctional materials have attracted tremendous attention in intelligent and interactive devices. However, achieving multi-dimensional sensing capabilities with the same perovskite quantum dot (PQD) material is still in its infancy, with some considering it currently challenging and even unattainable. Drawing inspiration from neurons, a novel multifunctional CsPbBr/PDMS nanosphere is devised to sense humidity, temperature, and pressure simultaneously with unique interactive responses.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!