Gastric Emptying Scintigraphy: Diagnostic Value of Delayed Imaging and the Impact on Reclassification of Diagnosis.

Mol Imaging Radionucl Ther

Department of Nuclear Medicine, Taleghani Hospital Clinical Research Development Unit, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Published: June 2023

Objectives: To investigate the added diagnostic value of delayed imaging at 3 and 4 h compared to 2 h imaging as well as scanning up to 4 h compared to 3, and by this means, diagnosis reclassification or changes in diagnosis across various time points.

Methods: Seventeen patients clinically suspected of gastroparesis, 8 (47.1%) men and 9 (52.9%) women, according to the standard procedural guidelines, underwent gastric emptying scintigraphy after ingesting a standard meal. One-minute static images in anterior and posterior projections were acquired immediately after ingestion and then at 1-, 2-, 3- , and 4 h time points. For image analysis, a manual region-of-interest was drawn, and then, count of stomach in each projection was used to calculate geometric mean for each time point. Decay correction was applied. At 2-, 3- and 4 h time points, percentage of retained activity was compared to standard values; therefore, each patient was labeled as normal or delayed.

Results: Pairwise correlation between time points was statistically significant. Value of hour 3 shows an extremely strong correlation with the value of hour 4 (r=0.951, p<0.001). In hour 2, of 17 participants, 11 (64.7%) were diagnosed as normal and 6 (35.3%) as delayed. In hour 3, the diagnosis made as delayed rose to 9 (52.9%), whereas normal was 8 (47.1%). Finally, in hour 4, results were 10 (58.8%) as delayed and 7 (41.2%) as normal. All subjects who were labeled as delayed in hour 3 remained with the same diagnosis and 1 out of 8 subjects categorized as normal in hour 3 changed to delayed. For testing agreement, coefficient of kappa was computed between each pair. Agreement between diagnosis in hour 2 with hours 3 or 4 was not strong (kappa <0.6 for both pairs). However, a strong agreement was found between diagnosis in hours 3 and 4 (kappa: 0.881).

Conclusion: Because of excellent correlation between values of hours 3 and 4 and strong agreement between the diagnosis in those time points, extending acquisition from 3 to 4 h adds little to the final dai gnosis and may not be noticeably meaningful, especially in the clinical setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10284173PMC
http://dx.doi.org/10.4274/mirt.galenos.2021.65902DOI Listing

Publication Analysis

Top Keywords

time points
12
gastric emptying
8
emptying scintigraphy
8
diagnostic delayed
8
delayed imaging
8
time
5
scintigraphy diagnostic
4
imaging impact
4
impact reclassification
4
reclassification diagnosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!