Objectives: The aim of this study was to compare the treatment responses after ablation with 30-50 mCi radioactive iodine (RAI) and 100 mCi RAI in patients with differentiated thyroid cancer (DTC) who were in the low-risk group according to 2015 American Thyroid Associations Classification (ATA 2015) criteria.
Methods: Between February 2016 and August 2018, 100 patients who received RAI treatment in our clinic after total thyroidectomy and who were in the low-risk group DTC were included in this retrospective study. These patients were divided into 2 groups: low-activity (30-50 mCi) (group 1) and high-activity (100 mCi) (group 2). While 54 patients were treated with low activity, 46 patients received high activity RAI. The 2 groups were compared according to the 1- and 3-year treatment response status.
Results: According to the first-year follow-up, 15 patients were accepted as indeterminate response and 85 patients as excellent response. Three (5.5%) of the patients who were accepted as indeterminate response were in group 1 and 12 (26%) were in group 2. According to the third year follow-up, 1 patient in group 1 and 3 patients in group 2 were accepted as indeterminate response. No biochemical incomplete response or recurrent disease was detected. In the chi-square analysis performed to investigate the relationship between the first-year treatment response and RAI activities, a significant relationship was found (p=0.004). In the Mann-Whitney U test performed to investigate the parameters that may be effective in the treatment response, only the preablative serum thyroglobulin value was shown to have a significant difference between the two groups (p=0.01). In the long-term follow-up of the patients, based on the third year treatment response data, chi-square analysis was performed to evaluate the two groups in terms of treatment responses, and no statistically significant relationship was found (p=0.73).
Conclusion: Ablation with 30-50 mCi can be safely applied in DTC patients who are in the ATA 2015 low-risk group and are planned for RAI ablation treatment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10284181 | PMC |
http://dx.doi.org/10.4274/mirt.galenos.2022.05826 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!