Background: Endotracheal tube (ETT) malposition is frequent in paediatric intubation. The current recommendations for ETT insertion depths are based on formulae that hold various limitations. This study aimed to develop age-based, weight-based and height-based curve charts and tables for ETT insertion depth recommendations in children.

Methods: In this retrospective single-centre study, we determined the individual optimal ETT insertion depths in paediatric patients by evaluating postintubation radiographic images. Age-based, weight-based and height-based ETT insertion depth recommendations were developed using regression analysis. We compared the insertion depths predicted by the models with previously published formulae.

Results: Intubations of 167 children (0-17.9 years) were analysed. Best-fit curves generated with logistic regression analysis revealed R values between 0.784 and 0.880. The insertion depths predicted by the models corresponded well with published age-based and height-based formulae. However, they demonstrated the unsuitability of weight-related linear formulae to predict ETT depth in children.

Conclusion: The recommendations developed in this study facilitate a fast and accurate determination of recommended ETT insertion depths in children. Our recommendations provide greater accuracy than previously published formulae and demonstrate that weight-related linear formulae are unsuitable for predicting ETT depth in children.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10423483PMC
http://dx.doi.org/10.1136/emermed-2022-212494DOI Listing

Publication Analysis

Top Keywords

insertion depths
24
ett insertion
20
endotracheal tube
8
insertion
8
depths children
8
ett
8
age-based weight-based
8
weight-based height-based
8
insertion depth
8
depth recommendations
8

Similar Publications

Background: In this study, we present an in-depth analysis of the Eurasian minnow (Phoxinus phoxinus) genome, highlighting its genetic diversity, structural variations, and evolutionary adaptations. We generated an annotated haplotype-phased, chromosome-level genome assembly (2n = 50) by integrating high-fidelity (HiFi) long reads and chromosome conformation capture data (Hi-C).

Results: We achieved a haploid size of 940 megabase pairs (Mbp) for haplome 1 and 929 Mbp for haplome 2 with high scaffold N50 values of 36.

View Article and Find Full Text PDF

This paper presents the design and experimental verification of a terahertz (THz) spoof surface plasmon polariton (SSPP) waveguide using a coplanar stripline (CPS) with internal corrugations and is compared against an external corrugation configuration. Internal corrugations are selected to reduce the insertion loss by improving the mode conversion efficiency of the transition circuit. We examine this effect using simulation and then experimentally confirm that the SSPP mode was excited for two different corrugation depths, 55 µm, and 65 µm.

View Article and Find Full Text PDF

The protective effect of wearing hearing protection devices in noise-induced hearing loss and its potential influencing factors in the Chinese adult population.

Sci Total Environ

January 2025

Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou, Guangdong, China; Guangdong Medical University, Dongguan, Guangdong, China; Guangdong Pharmaceutical University, Guangzhou, Guangdong, China; Southern Medical University, Guangzhou, Guangdong, China; JI NAN University, Guangdong, China. Electronic address:

Background: Noise is a threat to human auditory system, hearing protection devices (HPDs) are widely used to prevent noise-induced hearing loss (NIHL). However, the role of wearing HPDs on NIHL and the complex relationship between them are still unclear. This study aims to explore such relationship and identify the associated influencing pathways.

View Article and Find Full Text PDF

Five-Year Results of One-Piece Zirconia Oral Implants Supporting Three-Unit Fixed Dental Prostheses.

Clin Oral Implants Res

January 2025

Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Freiburg, Germany.

Objectives: The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one-piece zirconia implants fabricated from 3Y-TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three-unit fixed dental prostheses (FDP) after five years in function.

Materials And Methods: Twenty-seven patients received a total of 54 implants in a one-stage surgery with immediate provisionalization.

View Article and Find Full Text PDF

Background: Normothermic ex situ heart perfusion (ESHP) has emerged as a valid modality for advanced cardiac allograft preservation and conditioning prior to transplantation though myocardial function declines gradually during ESHP thus limiting its potential for expanding the donor pool. Recently, the utilization of dialysis has been shown to preserve myocardial and coronary vasomotor function. Herein, we sought to determine the changes in myocardial metabolism that could support this improvement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!