Background: Atrial linear scars in Cox-Maze IV procedures are achieved using Cryothermy (Cryo) or radiofrequency (RF) techniques. The subsequent postoperative left atrial (LA) reverse remodelling is unclear. We used 2- and 3-dimensional echocardiography (2-3DE) to compare the impact of Cryo and RF procedures on LA size and function 1 year after Cox-maze IV ablation concomitant with Mitral valve (MV) surgery.
Methods: Seventy-two patients with MV disease and AF were randomized to Cryo (n = 35) or RF (n = 37) ablation. Another 33 patients were enroled without ablation (NoMaze). All patients underwent an echocardiogram the day before and 1 year after surgery. The LA function was assessed on 2D strain by speckle tracking and 3DE.
Results: Forty-two ablated patients recovered sinus rhythm (SR) 1 year after surgery. They had comparable left and right systolic ventricular function, LA volume index (LAVI), and 2D reservoir strain before surgery. At follow-up, the 3DE extracted reservoir and booster function were higher after RF (37 ± 10% vs. 26 ± 6%; p < 0.001) than Cryo ablation (18 ± 9 vs. 7 ± 4%; p < 0.001), while passive conduit function was comparable between groups (24 ± 11 vs. 20 ± 8%; p = 0.17). The extent of LAVI reduction depended on the duration of AF preoperatively.
Conclusions: SR restoration after MV surgery and maze results in LA size reduction irrespective of the energy source used. Compared to RF, the extension of ablation area produced by Cryo implies a structural LA remodelling affecting LA systolic function.