Neutral detergent fiber (NDF) is the most commonly reported metric for fiber in dairy cattle nutrition. An empirical method, NDF is defined by the procedure used to measure it. The current definitive method for NDF treated with amylase (aNDF) is AOAC Official Method 2002.04 performed on dried samples ground through the 1-mm screen of a cutting mill with refluxing and then filtration through Gooch crucibles without (AOAC-; reference method) or with (AOAC+) a glass fiber filter filtration aid. Other methods in use include grinding materials through the 1-mm screen of an abrasion mill, using filtration through a Buchner funnel with a glass fiber filter (Buch), and use of the ANKOM system (ANKOM Technology, Macedon, NY) that simultaneously extracts and filters samples through filter bags with larger (F57) or smaller (F58) particle size retentions. Our objective was to compare the AOAC and alternative methods using samples ground through the 1-mm screens of cutting or abrasion mills. Materials analyzed were 2 alfalfa silages, 2 corn silages, dry ground and high-moisture corn grains, mixed grass hay, ryegrass silage, soybean hulls, calf starter, and sugar beet pulp. Samples were run in duplicate in replicate analytical runs performed on different days by experienced technicians. Compared with cutting mill-ground samples, the aNDF% of dry matter results from abrasion mill-ground samples were or tended to be lower for 8 of 11 samples. Method affected aNDF% results for all materials, with method × grind interactions for 6 of 11 samples. For ash-free aNDF% assessed with cutting mill-ground materials, a priori selected contrasts showed that the number of materials for which methods differed or tended to differ from the AOAC methods were 4 (Buch), 8 (F57), and 3 (F58); and 3 for AOAC- versus AOAC+. However, statistically different does not necessarily mean substantially different. For a given feed and grind, a positive value for the absolute difference between the AOAC- mean and an alternative method mean minus 2 times the standard deviation of AOAC- suggests that values for the alternative method fall outside of the range of results likely to be observed for the reference method. The number of observed positive values for materials processed with cutting and abrasion mills, respectively, were 0 and 2 (AOAC+); 2 and 2 (Buch); 8 and 10 (F57); 4 and 7 (F58); and 0 and 4 (AOAC-). With the materials tested, methods in order of agreement with the reference method were Buch, F58, and F57, which often gave lower values. The AOAC+ gave results similar to AOAC-, substantiating it as an allowed modification of AOAC-. Best agreement between the reference method and variant NDF methods was achieved with the 1-mm screen cutting mill grind. The 1-mm abrasion mill grind produced more aNDF% results that were lower than the reference method but with fewer differences when filter particle retention size was smaller. The use of filters that retain finer particles could be explored to improve comparability of variant NDF methods and grinds. Further evaluation with an expanded set of materials is warranted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3168/jds.2022-22847 | DOI Listing |
Anal Bioanal Chem
January 2025
Division Biophotonics, Federal Institute for Materials Research and Testing (BAM), Richard-Willstaetter-Str. 11, 12489, Berlin, Germany.
The rational design of engineered nanomaterials (NMs) with improved functionality and their increasing industrial application requires reliable, validated, and ultimately standardized characterization methods for their application-relevant, physicochemical key properties such as size, size distribution, shape, or surface chemistry. This calls for nanoscale (certified) reference materials (CRMs; RMs) and well-characterized reference test materials (RTMs) termed also quality control (QC) samples, assessed, e.g.
View Article and Find Full Text PDFEur J Clin Microbiol Infect Dis
January 2025
Department of Ultrasound Medicine, Guangdong Provincial Key Laboratory of Major Obstetric Diseases, Guangdong Provincial Clinical Research Center for Obstetrics and Gynecology, The Third Affiliated Hospital, Guangzhou Medical University, Guangzhou, 510150, China.
Background: Public health issues related to tuberculosis still exist. Because Xpert MTB/RIF Ultra is more effective than conventional TB diagnostic techniques are, it is now regarded as an emerging technology. The diagnostic accuracy of Xpert MTB/RIF Ultra for tuberculosis was assessed in this systematic study.
View Article and Find Full Text PDFAnal Chem
January 2025
State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu 611137, China.
Quaternary ammonium salts (QAs) are a class of highly active compounds widely used in medicine and agriculture. However, many QAs lack a conjugated system, making their recognition and quantitation challenging. Stachydrine is a representative unconjugated QA with a high content in Houtt.
View Article and Find Full Text PDFObjective: ADHD is one of the most common neurodevelopmental disorders, seen in children and adolescents, and is often treated with various pharmacological agents, especially methylphenidate. There are differing opinions in the literature regarding the cardiovascular safety of long-term methylphenidate use. Studies suggest that the drug may increase the risk of hypertension, myocardial infarction, ventricular arrhythmia, sudden cardiac death, cardiomyopathy, heart failure (HF), pulmonary hypertension, and stroke.
View Article and Find Full Text PDFPaediatr Anaesth
January 2025
Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Background: Children who need to have major surgery or are critically ill often require the insertion of a central venous catheter (CVC). To avoid serious complications, it is important to correctly position the CVC tip at the junction of the distal superior vena cava and the right atrium (cavoatrial junction). Transthoracic echocardiography (TTE) can be used to confirm the correct position of the CVC tip.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!