Objective: Deep vein thrombosis is a common and serious complication associated with midline catheters (MC). The aim of this investigation was to determine if catheter diameter is related to development of thrombosis.
Methods: This was an observational cohort study conducted at a tertiary care academic center in Southeastern Michigan. Hospitalized adults that required a MC were eligible participants. Primary outcome was symptomatic MC associated upper extremity deep vein thrombosis (DVT) comparing three catheter diameters. Secondary outcomes included complications based on size and DVT comparing catheter to vein ratio.
Results: Between January 1, 2017, and December 31, 2021, 3088 MCs met inclusion criteria; the distribution of 3 French (Fr), 4 Fr, and 5 Fr MCs was 35.1 %, 57.0 %, and 7.9 %, respectively. The majority of the population was female (61.2 %) and the average age was 64.2 years old. DVT occurred in 4.4 %, 3.9 %, and 11.9 % of 3 Fr, 4 Fr, and 5 Fr MCs, respectively (p < 0.001). In multivariable regression analysis, there was no difference in the odds of developing DVT for the 4 Fr MC compared to the 3 Fr (aOR 0.88; 95 % CI 0.59-1.31; p = 0.5243), however, there was significantly higher odds for the 5 Fr (aOR 2.72; 95 % CI 1.62-4.51; p = 0.001). Additionally, for every additional day the MC was in place, the odds of DVT increased by 3 % (aOR 1.03; 95 % CI 1.01-1.05; p = 0.0039). When comparing accuracy of the size model versus catheter to vein ratio model for predicting DVT, receiver operating characteristic curve analysis demonstrated the area under the curve for size was 73.70 % (95 % CI 68.04 %-79.36 %) compared to 73.01 % (95 % CI: 66.88 %-79.10 %) for catheter-to-vein ratio.
Conclusions: Smaller diameter catheters should be preferentially chosen to mitigate the risk of thrombosis when therapy via midline catheters is required. Choosing a catheter based on reduced size or 1:3 catheter to vein ratio threshold has similar accuracy in predicting DVT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.thromres.2023.06.007 | DOI Listing |
Acta Neurochir (Wien)
January 2025
Division of Neuroradiology and Joint Department of Medical Imaging, University Health Network and Toronto Western Hospital, Toronto, ON, M5T 2S8, Canada.
Purpose: It was noticed that anterior choroidal artery (AChoA) aneurysms appear to rupture at relatively smaller sizes compared with aneurysms in other intracranial locations, based on anecdotal clinical experience. We therefore aimed to compare ruptured AChoA aneurysms with other ruptured aneurysms in other intracranial locations, pertaining to aneurysm dimensions. This may help in finding out if the rupture risk stratification, based on the amalgamation of aneurysms of multiple locations in one group, precisely estimates aneurysm rupture risk.
View Article and Find Full Text PDFEgypt Heart J
January 2025
Department of Cardiology, Lianyungang No 1 People's Hospital, No. 6 East Zhenhua Road, Haizhou District, Lianyungang, 222061, Jiangsu, China.
Background: The rate at which atrial fibrillation (AF) patients experience a return of symptoms after catheter ablation is significant, and there are multiple risk factors involved. This research intends to perform a meta-analysis to explore the risk factors connected to the recurrence of AF in patients following catheter ablation.
Methods: The PubMed, Cochrane Library, WOS, Embase, SinoMed, CNKI, Wanfang, and VIP databases were explored for studies from January 1, 2000 to August 10, 2021, and research meeting the established inclusion requirements was chosen.
J Mech Behav Biomed Mater
January 2025
Department of Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada; Sunnybrook Research Institute, Toronto, Canada.
The integration of self-expandable nitinol frames with cable-driven parallel mechanisms offers a promising advancement in minimally invasive cardiovascular interventions. This study presents the design, fabrication, and verification of a miniaturized self-expandable nitinol frame to enhance catheter tip steerability and navigation within complex vascular anatomies. The frame is reduced in size for delivery through 7-8 Fr sheaths while accommodating diverse vascular diameters, allowing up to a maximum expansion of 15 mm.
View Article and Find Full Text PDFUrolithiasis
January 2025
Department of Urology, University of Michigan, 1500 E. Medical Center Drive, Ann Arbor, MI, 48109-5330, USA.
Understanding renal pelvis pressure (P) during ureteroscopy (URS) has become increasingly important. High irrigation rates, desirable to maintain visualization and limit thermal dose, can increase P. Use of a multi-channel ureteroscope (m-ureteroscope) with a dedicated drainage channel is one strategy that may facilitate simultaneous low P and high flowrate.
View Article and Find Full Text PDFSci Rep
January 2025
Minnova Medical Foundation CIC, Wilmslow, UK.
A variety of medical specialities undertake percutaneous drainage but understanding of device performance outside radiology is often limited. Furthermore, the current catheter sizing using the "French" measurement of outer diameter is unhelpful; it does not reflect the internal diameter and gives no information on flow rate. To illustrate this and to improve catheter selection, notably for chest drainage, we assessed the variation of drain performance under standardised conditions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!