AI Article Synopsis

  • Real-time fMRI neurofeedback (rt-fMRI-NF) is a new way to help people control their brain activity, which can be useful for fighting cravings, like those for alcohol.
  • In a study with 30 adults who have alcohol use disorder, they tested different methods of neurofeedback to see which worked best to reduce cravings.
  • The results showed that using multi-region feedback helped participants the most, and that practicing more led to better control over their cravings, but more research is needed to fully understand its benefits.

Article Abstract

Real-time fMRI neurofeedback (rt-fMRI-NF) is a technique in which information about an individual's neural state is given back to them, typically to enable and reinforce neuromodulation. Its clinical potential has been demonstrated in several applications, but lack of evidence on optimal parameters limits clinical utility of the technique. This study aimed to identify optimal parameters for rt-fMRI-NF-aided craving regulation training in alcohol use disorder (AUD). Adults with AUD (n = 30) participated in a single-session study of four runs of rt-fMRI-NF where they downregulated "craving-related" brain activity. They received one of three types of neurofeedback: multi-region of interest (ROI), support vector machine with continuous feedback (cSVM), and support vector machine with intermittent feedback (iSVM). Performance was assessed on the success rate, change in neural downregulation, and change in self-reported craving for alcohol. Participants had more successful trials in run 4 versus 1, as well as improved downregulation of the insula, anterior cingulate, and dorsolateral prefrontal cortex (dlPFC). Greater downregulation of the latter two regions predicted greater reduction in craving. iSVM performed significantly worse than the other two methods. Downregulation of the striatum and dlPFC, enabled by ROI but not cSVM neurofeedback, was correlated with a greater reduction in craving. rt-fMRI-NF training for downregulation of alcohol craving in individuals with AUD shows potential for clinical use, though this pilot study should be followed with a larger randomized-control trial before clinical meaningfulness can be established. Preliminary results suggest an advantage of multi-ROI over SVM and intermittent feedback approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1111/psyp.14367DOI Listing

Publication Analysis

Top Keywords

real-time fmri
8
fmri neurofeedback
8
alcohol craving
8
optimal parameters
8
support vector
8
vector machine
8
intermittent feedback
8
greater reduction
8
reduction craving
8
craving
6

Similar Publications

Background: Real-time (RT) phase contrast (PC) flow MRI can potentially be used to measure blood flow in arrhythmic patients. Undersampled RT PC has been combined with online compressed sensing (CS) reconstruction (CS RT) enabling clinical use. However, CS RT flow has not been validated in a clinical setting.

View Article and Find Full Text PDF

Clinical applications of nanoprobes of high-resolution imaging.

iScience

January 2025

Department of Thoracic Surgery, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Currently, the primary imaging methods used in clinical diagnosis are X-ray, computed tomography (CT), ultrasound, magnetic resonance imaging (MRI), PET-CT, etc. The sensitivity and accuracy of these imaging methods bring many difficulties in clinical diagnosis; at the same time, CT, X-ray, PET-CT, etc. can cause radiation to the human body; some invasive operations of the gold standard bring much pain to the patients.

View Article and Find Full Text PDF

Optical Imaging Guidance in Oncologic Surgery and Interventional Oncology.

Pharmacol Res

January 2025

Image-Guided Bio-Molecular Intervention Research and Division of Interventional Radiology, Department of Radiology, University of Washington School of Medicine, Seattle, USA. Electronic address:

Over recent decades, optical imaging (OI) has become an integral part of medical imaging, offering significant advantages over other modalities, such as computed tomography (CT) and magnetic resonance imaging (MRI). OI is distinguished by its real-time imaging capability, cost-effectiveness, portability, absence of ionizing radiation, and high patient acceptability. The introduction of advanced optical dyes (including FDA-approved agents like indocyanine green, Cytalux, and Gleolan) has greatly enhanced its clinical utility.

View Article and Find Full Text PDF

Quantitative pre-clinical imaging of hypoxia and vascularity using MRI and PET.

Methods Cell Biol

January 2025

Translational Radiomics, Luxembourg Institute of Health, Luxembourg City, Luxembourg; In-Vivo Imaging Platform, Luxembourg Institute of Health, Luxembourg City, Luxembourg.

During hypoxia, tissues are subjected to an inadequate oxygen supply, disrupting the balance needed to maintain normal function. This deficiency can occur due to reduced oxygen delivery caused by impaired blood flow or a decline in the blood's ability to carry oxygen. In tumors, hypoxia and vascularization play crucial roles, shaping their microenvironments and influencing cancer progression, response to treatment and metastatic potential.

View Article and Find Full Text PDF

PEGylated Ultrasmall Iron Oxide Nanoparticles as MRI Contrast Agents for Vascular Imaging and Real-Time Monitoring.

ACS Nano

January 2025

Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.

Accurate imaging evaluations of pre- and post-treatment of cardiovascular diseases are pivotal for effective clinical interventions and improved patient outcomes. However, current imaging methods lack real-time monitoring capabilities with a high contrast and resolution during treatments. This study introduces PEGylated ultrasmall iron oxide nanoparticles (PUSIONPs), which have undergone comprehensive safety evaluations, boasting an value of 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!