Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10266378PMC
http://dx.doi.org/10.4244/EIJ-E-23-00015DOI Listing

Publication Analysis

Top Keywords

bioresorbable coronary
4
coronary scaffolds
4
scaffolds ready
4
ready comeback
4
comeback pros
4
pros cons
4
bioresorbable
1
scaffolds
1
ready
1
comeback
1

Similar Publications

Introduction And Objectives: Patients undergoing percutaneous coronary intervention in vessels with moderate-to-severe tortuosity are at higher risk of adverse outcomes, but data are scarce in the era of newer-generation stents. We compared outcomes following percutaneous coronary intervention in vessels with moderate-to-severe tortuosity using a bioresorbable-polymer sirolimus-eluting stent (BP-SES) vs a durable-polymer everolimus-eluting stent.

Methods: A total of 2350 patients from the BIOFLOW II, IV, and V randomized trials were stratified into 2 groups based on target-vessel tortuosity: none-to-mild and moderate-to-severe.

View Article and Find Full Text PDF
Article Synopsis
  • Neointimal coverage and stent apposition are critical for improving percutaneous coronary interventions (PCI), but current algorithms struggle with automating the analysis of diverse stent types and preselecting necessary segments.
  • This study introduces TriVOCTNet, a multi-task deep learning model designed to automate the classification, lumen segmentation, and stent strut segmentation in IVOCT images, all within one efficient network.
  • TriVOCTNet demonstrated impressive accuracy with high classification rates and precise segmentation outputs, indicating its potential for enhancing clinical practices in PCI procedures.
View Article and Find Full Text PDF

Polymeric coronary stents, like the ABSORB™, are commonly used to treat atherosclerosis due to their bioresorbable and cell-compatible polymer structure. However, they face challenges such as high strut thickness, high elastic recoil, and lack of radiopacity. This study aims to address these limitations by modifying degradable stents produced by additive manufacturing with poly(lactic acid) (PLA) and poly(ε-caprolactone) (PCL) with degradable metallic coatings, specifically zinc (Zn) and magnesium (Mg), deposited via radiofrequency (rf) magnetron sputtering.

View Article and Find Full Text PDF

Limited evidence exists regarding the long-term outcomes of true versus nontrue coronary bifurcation lesions (CBLs) treated with current-generation drug-eluting stents and intravascular imaging guidance. The Sapporo Cardiovascular Clinic (SCVC) registry was a prospective, single-center, all-comers registry enrolling 1,727 consecutive patients treated with bioresorbable polymer sirolimus-eluting stent under complete imaging guidance. From this registry, 440 patients with CBLs (25.

View Article and Find Full Text PDF

The growing prevalence of coronary artery diseases in the US corresponds to the increasing use of minimally invasive techniques that require coronary stents. Although extensive research is available on the perioperative outcomes of the 3 stent options - bare-metal stents (BMS), drug-eluting stents (DES), and bioresorbable drug-eluting stents (BVS), a knowledge gap exists in the longitudinal monitoring of patient outcomes due to device-related causes. Therefore, our study examines the device-related patient outcome and the relative performance for BMS, DES, and BVS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!