A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High ionic strength dissociation assay reduces dimeric target interference in immunogenicity testing. | LitMetric

High ionic strength dissociation assay reduces dimeric target interference in immunogenicity testing.

Bioanalysis

Roche Pharma Research & Early Development (pRED), Pharmaceutical Sciences, Bioanalysis & Biomarkers, Roche Innovation Center Munich, Roche Diagnostics GmbH, Nonnenwald 2, Penzberg, 82377, Germany.

Published: July 2023

The presence of di-/multi-meric forms of soluble target in biological samples can interfere in anti-drug antibody (ADA) assays, leading to increased background values and potentially false positivity. The authors investigated the use of the high ionic strength dissociation assay (HISDA) to reduce target interference in two different ADA assays. Interference caused by homodimeric FAP was successfully eliminated to enable cut point determination after applying HISDA. Biochemical experiments confirmed the dissociation of homodimeric FAP after treatment with high ionic strength conditions. HISDA is a promising approach to simultaneously achieve high drug tolerance and reduced interference by noncovalently bound dimeric target molecules in ADA assays without extensive optimization, which is particularly advantageous in routine use.

Download full-text PDF

Source
http://dx.doi.org/10.4155/bio-2023-0082DOI Listing

Publication Analysis

Top Keywords

high ionic
12
ionic strength
12
ada assays
12
strength dissociation
8
dissociation assay
8
dimeric target
8
target interference
8
high
4
assay reduces
4
reduces dimeric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!