AI Article Synopsis

  • The study focuses on using a Contegra monocusp and native leaflet tissue to create a functioning pulmonary valve in children with severe tetralogy of Fallot, aiming to avoid the need for a transannular patch.
  • Eighteen patients were analyzed, with successful operations leading to good health post-surgery; most patients had a hospital stay averaging about 12.5 days, and complications included one death and several requiring catheter interventions.
  • Follow-up results showed significant improvements in pulmonary annulus sizes and a 79.25% freedom from dysfunction at 36 months, suggesting the method is effective and replicable for future procedures.

Article Abstract

Objective: Severe right ventricular outflow tract obstruction in tetralogy of Fallot and variants necessitates the use of transannular patch in a significant proportion of children undergoing repair. We have used a Contegra monocusp together with delamination of native leaflet tissue in order to create a functioning pulmonary valve.

Methods: In total, 18 (2017-2022) consecutive Contegra monocusp implantations were included. Median age and weight were 3.65 [2.00; 9.43] months and 6.12 [4.30; 8.22] kg, respectively. Nine of 18 patients had undergone palliation. Native pulmonary leaflet tissue was recruited to create a single posterior cusp. Contegra monocusp selection was based on the goal to achieve a neoannulus of Z value ≈ 0. Monocusp sizes implanted were 16 [14; 18] mm. Patch plasty of left pulmonary artery (LPA) (9), right pulmonary artery (RPA) (2), and both LPA-RPA (5) were often performed.

Results: All patients survived the operation and were discharged home in good health. Median ventilation time and hospital stay were 2 [1; 9] and 12.5 [9; 54] days, respectively. Follow-up duration was 30.68 [3.47; 60.47] months and 100% complete. One patient with well-corrected right ventricular outflow tract died 9.4 months postoperatively, possibly of aspiration. One child with membranous pulmonary atresia needed reoperation (conduit insertion) at 3.5 months of follow-up. Five needed catheter interventions: supravalvar stent (2), LPA stent (3), and RPA stent (1), most of them in the earlier half of the experience. Pulmonary annulus changed from preoperative -3.91 [-5.98; -2.23] to -0.10 [-1.44; 1.92] at discharge; growing proportionally to -0.13 [-3.52; 2.73] at follow-up. Kaplan-Meier freedom from composite dysfunction was 79.25 (95% confidence interval, +13.68%, -31.44%) at 36 months.

Conclusions: Recruitment of native leaflets, optimal Contegra monocusp, and commissuroplasty provide an easily replicable technique for achieving a competent, proportionally growing neopulmonary valve. Longer follow-up is needed to determine its impact on delaying a pulmonary valve replacement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10268230PMC
http://dx.doi.org/10.1016/j.xjtc.2023.03.013DOI Listing

Publication Analysis

Top Keywords

contegra monocusp
16
ventricular outflow
12
outflow tract
12
severe ventricular
8
tract obstruction
8
leaflet tissue
8
pulmonary artery
8
follow-up needed
8
pulmonary
7
monocusp
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!