Objective: This study aimed to test the inter-examiner and intra-examiner reliability of macular vascular density (VD) measurement of retinal and choriocapillaris plexuses in healthy children using optical coherence tomography angiography (OCTA).
Materials And Methods: Ninety-two school children were prospectively recruited. Macular OCTA images (6 × 6 mm) were obtained thrice by two examiners using the RTVue-XR Avanti OCT system. The coefficient of variation (COV), intraclass correlation coefficient (ICC), and Bland-Altman plots were used to evaluate the repeatability and reproducibility.
Results: Ninety participants aged 6-15 years were enrolled; two participants were excluded because of low-quality images. In the retina, the reproducibility and repeatability of VD became poorer from superficial to deep retinal capillary plexus (superficial: COV = 4.61-11.11%; intermediate: COV = 7.73-14.15%; deep: COV = 14.60-32.28%). For both reproducibility and repeatability, the ICC ranged from moderate to high (superficial plexus: ICC = 0.570-0.976; intermediate plexus: ICC = 0.720-0.968; deep plexus: ICC = 0.628-0.954). In the choroid, the inter-examiner reproducibility and intra-examiner repeatability of the VD measurement of choriocapillaris were excellent in the macula, fovea, parafovea, and perifovea (COV = 1.00-6.10%; ICC = 0.856-0.950). The parameters of the foveal avascular zone (FAZ) also showed significant reproducibility and repeatability (COV = 0.01-0.21%; ICC = 0.743-0.994).
Conclusion: The VD measurements of the choriocapillaris and FAZ parameters using OCTA showed excellent inter-examiner and intra-examiner reliability in school children. The reproducibility and repeatability of the VD of three retinal capillary plexuses depended on the depth of the retinal capillary plexus.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10267442 | PMC |
http://dx.doi.org/10.3389/fmed.2023.1161942 | DOI Listing |
Sensors (Basel)
January 2025
Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.
(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Construction Materials Engineering Department, Instytut Techniki Budowlanej, 00-611 Warsaw, Poland.
Many test methods used in the assessment of construction products are characterised by poor precision, which is reflected in the discrepancies of results obtained by different laboratories. The test procedure for fungal resistance of natural particle-reinforced composite construction profiles has not been fully specified, which may lead to such discrepancies and erroneous utility assessment. In this study, the precision of the method and the influence of the mycelium removal on the fungal resistance were assessed based on the flexural strength and modulus of elasticity test results obtained for millet- and oat husk-reinforced PVC composites exposed to .
View Article and Find Full Text PDFPhysiol Meas
January 2025
Department for Psychosomatic Medicine and Psychotherapy, Universitatsklinikum Jena, Philosophenweg 3, Jena, Thüringen, 07743, GERMANY.
Heart rate variability (HRV) is an important indicator of cardiac autonomic function. Given its clinical significance, reliable HRV assessment is crucial. Here, we assessed test-retest stability, as a key aspect of reliability, quantifying the consistency of a measure when repeated under the same conditions.
View Article and Find Full Text PDFJ Med Internet Res
January 2025
Division of General Internal Medicine, Mayo Clinic College of Medicine and Science, 200 First St SW, Rochester, US.
Background: Virtual patients (VPs) are computer screen-based simulations of patient-clinician encounters. VP use is limited by cost and low scalability.
Objective: Show proof-of-concept that VPs powered by large language models (LLMs) generate authentic dialogs, accurate representations of patient preferences, and personalized feedback on clinical performance; and explore LLMs for rating dialog and feedback quality.
Eur J Trauma Emerg Surg
January 2025
Department of Orthopaedic Surgery, Hyogo Prefectural Nishinomiya Hospital, 13-9, Rokutanji, Nishinomiya, 662-0918, Japan.
Purpose: Evaluating sacral fractures is crucial in fragility fractures of the pelvis. Dual-energy CT (DECT) is considered useful for diagnosing unclear fractures on single-energy CT (SECT). This study aims to investigate the effectiveness of DECT in diagnosing sacral fractures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!