Medical ultrasound is of increasing importance in medical diagnosis and intraoperative assistance and possesses great potential advantages when integrated with robotics. However, some concerns, including the operation efficiency, operation safety, image quality, and comfort of patients, remain after introducing robotics into medical ultrasound. In this paper, an ultrasound robot integrating a force control mechanism, force/torque measurement mechanism, and online adjustment method, is proposed to overcome the current limitations. The ultrasound robot can measure operating forces and torques, provide adjustable constant operating forces, eliminate great operating forces introduced by accidental operations, and achieve various scanning depths based on clinical requirements. The proposed ultrasound robot would potentially facilitate sonographers to find the targets quickly, improve operation safety and efficiency, and decrease patients' discomfort. Simulations and experiments were carried out to evaluate the performance of the ultrasound robot. Experimental results show that the proposed ultrasound robot is able to detect operating force in the z-direction and torques around the x- and y- directions with errors of 3.53% F.S., 6.68% F.S., and 6.11% F.S., respectively, maintain the constant operating force with errors of less than 0.57N, and achieve various scanning depths for target searching and imaging. This proposed ultrasound robot has good performance and would potentially be used in medical ultrasound.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7614653PMC
http://dx.doi.org/10.1109/TIM.2023.3239925DOI Listing

Publication Analysis

Top Keywords

ultrasound robot
28
medical ultrasound
12
operating forces
12
proposed ultrasound
12
ultrasound
9
force/torque measurement
8
operation safety
8
constant operating
8
achieve scanning
8
scanning depths
8

Similar Publications

Background: To examine the feasibility and safety of the SENSEI drop-in gamma probe for robot-assisted, prostate-specific membrane antigen (PSMA)-radioguided salvage surgery (RGS) in lymph node or local oligorecurrent prostate cancer (PCa), detected via PSMA positron emission tomography/computed tomography (PET/CT).

Methods: The first thirteen patients with pelvic oligorecurrent PCa who underwent [Tc]Tc-PSMA-I&S RGS using the SENSEI drop-in gamma probe at the Martini-Klinik (February-June 2024) were retrospectively analyzed. Radioactivity measurements in counts per second (CPS) as absolute values or ratios (CPS of tumor specimens/mean CPS from the patients' benign tissues) were correlated with preoperative imaging and pathological findings (benign/malignant, lesion size).

View Article and Find Full Text PDF

Primary endometrial squamous cell carcinoma (PESCC): Review of the literature and case report.

Taiwan J Obstet Gynecol

January 2025

Department of Obstetrics and Gynecology, Taipei Medical University Hospital, Taipei, Taiwan; Department of Obstetrics and Gynecology, College of Medicine, Taipei Medical University, Taipei, Taiwan. Electronic address:

Objective: Primary endometrial squamous cell carcinoma (PESCC) is an extremely rare type of endometrial cancer with limited research and understanding. This report presents a case of PESCC and reviews 37 cases from 1997.

Case Report: A 61-year-old menopausal woman presented with abnormal vaginal bleeding.

View Article and Find Full Text PDF

Patient-specific templating (PST), which is a sister procedure to patient-specific instrumentation (PSI) but hospital-based, is relatively less complex and less expensive than robotics and navigation. However, there are some concerns about the PST including the process of preoperative planning, 3D printing and material, positioning of PST intraoperatively, availability, and clinical value. The purpose of this study was to validate the technical accuracy and reliability of the PST technique in the lab and to report the outcomes of clinical application.

View Article and Find Full Text PDF

Robotic-assisted thoracic surgery has become increasingly utilized in recent years. Complex lung cancer resection surgery can be performed using a robotic approach. It facilitates 3-dimentional visualization of structures, enhanced manipulation of tissues and precise movements.

View Article and Find Full Text PDF

Background And Purpose: Working memory, a primary cognitive domain, is often impaired in pediatric brain tumor survivors, affecting their attention and processing speed. This study investigated the long-term effects of treatments, including surgery, radiotherapy (RT), and chemotherapy (CT), on working memory tracts in children with posterior fossa tumors (PFTs) using resting-state functional MRI (rs-fMRI) and diffusion MRI tractography.

Methods: This study included 16 medulloblastoma (MB) survivors treated with postoperative RT and CT, 14 pilocytic astrocytoma (PA) survivors treated with surgery alone, and 16 healthy controls from the Imaging Memory after Pediatric Cancer in children, adolescents, and young adults study (NCT04324450).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!