Wearable ion sensors for the real-time monitoring of sweat biomarkers have recently attracted increasing research attention. Here, we fabricated a novel chloride ion sensor for real-time sweat monitoring. The printed sensor was heat-transferred onto nonwoven cloth, allowing for easy attachment to various types of clothing, including simple garments. Additionally, the cloth prevents contact between the skin and the sensor and acts as a flow path. The change in the electromotive force of the chloride ion sensor was -59.5 mTV/log . In addition, the sensor showed a good linear relationship with the concentration range of chloride ions in human sweat. Moreover, the sensor displayed a Nernst response, confirming no changes in the film composition due to heat transfer. Finally, the fabricated ion sensors were applied to the skin of a human volunteer subjected to an exercise test. In addition, a wireless transmitter was combined with the sensor to wirelessly monitor ions in sweat. The sensors showed significant responses to both sweat perspiration and exercise intensity. Thus, our research demonstrates the potential of using wearable ion sensors for the real-time monitoring of sweat biomarkers, which could significantly impact the development of personalized healthcare.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10391709PMC
http://dx.doi.org/10.1021/acssensors.3c01027DOI Listing

Publication Analysis

Top Keywords

ion sensors
16
wearable ion
12
sensors real-time
8
real-time monitoring
8
monitoring sweat
8
sweat biomarkers
8
chloride ion
8
ion sensor
8
sweat
7
sensor
7

Similar Publications

For optimizing production yield while limiting negative environmental impact, sustainable agriculture benefits from real-time, on-the-spot chemical analysis of soil at low cost. Colorimetric paper sensors are ideal candidates, however, their automated readout and analysis in the field is needed. Using mobile technology for paper sensor readout could, in principle, enable the application of machine-learning models for transforming colorimetric data into threshold-based classes that represent chemical concentration.

View Article and Find Full Text PDF

By a simple condensation reaction, the receptor with anthraquinone moiety was synthesized and its sensing properties were explored in the anion sensing studies via colorimetric, UV-vis studies, fluorescence studies, and DFT calculations. The synthesized receptor senses both acetate and hypochlorite ions in DMSO medium. By the addition of all anions into the receptor the colour change was observed from pink to light purple colour for acetate ion and pink to light blue for hypochlorite ion.

View Article and Find Full Text PDF

A double probe-based fluorescence sensor array to detect rare earth element ions.

Analyst

January 2025

Fujian Key Laboratory of Drug Target Discovery and Structural and Functional Research, School of Pharmacy, Fujian Medical University, Fuzhou 350004, China.

There is a persistent need for effective sensors to detect rare earth element ions (REEIs) due to their effects on human health and the environment. Thus, a simple and efficient fluorescence-based detection method for REEIs that offers convenience, flexibility, versatility, and efficiency is essential for ensuring environmental safety, food quality, and biomedical applications. In this study, 6-aza-2-thiothymine-gold nanoclusters (ATT-AuNCs) and bovine serum albumin/3-mercaptopropionic acid-AuNCs (BSA/MPA-AuNCs) were utilized to detect 14 REEIs (Sc, Gd, Lu, Y, Ce, Pr, Yb, Dy, Tm, Sm, Ho, Tb, La, and Eu), resulting in the creation of a simple, sensitive, and multi-target fluorescence sensor array detection platform.

View Article and Find Full Text PDF

Electrodes functionalised with weak electroactive microorganisms offer a viable alternative to conventional chemical sensors for detecting priority pollutants in bioremediation processes. Biofilm-based biosensors have been proposed for this purpose. However, biofilm formation and maturation require 24-48 h, and the microstructure and coverage of the electrode surface cannot be controlled, leading to poorly reproducible signal and sensitivity.

View Article and Find Full Text PDF

Infectious diseases pose a growing challenge in healthcare, with the increasing rate of antimicrobial resistance limiting therapeutic options available for treatment. Rapid detection of infections at the earliest opportunity can significantly improve patient outcomes. In this report, ion current rectifying quartz nanopipettes with ca.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!