A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dialyzer reprocessing: Considerations and pitfalls for effective and safe hemodialysis. | LitMetric

Dialyzer reprocessing: Considerations and pitfalls for effective and safe hemodialysis.

Semin Dial

Division of Nephrology, Department of Medicine, King Chulalongkorn Memorial Hospital, Thai Red Cross Society and Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.

Published: June 2023

Background: Dialyzer reprocessing for dialyzer reuse in the same patient has been developed since the early time in hemodialysis history to save cost and time related to reassembling the new dialyzer during that time. The procedure can reduce the first-use and allergic reactions from using incompatible cellulosic dialyzer membrane by altering some manufacturing chemicals.

Methods: All of established literatures regarding recent dialyzer reprocessing methods and considerations were extensively reviewed and summarized.

Results: Dialyzer reprocessing can be performed by multiple protocols but involves common steps including bedside rinsing after use, cleaning, dialyzer testing to prevent excessive drop in dialyzer clearance and membrane integrity, high-level disinfection or sterilization either by chemicals or heat, storage, and preparation for subsequent dialysis session by adequate rinsing to reduce the residual reprocessing chemical to the safe level. Compared with the single-use strategy, evidence is conflicting for the mortality advantages or disadvantages of dialyzer reuse, with some showing increased mortality in patients receiving peracetic acid sterilization. Keys for the effective and safe dialyzer reuse involve strict adherence to specific manufacturer's protocol, adequate dialysis water quality complied with the Association for the Advancement of Medical Instrumentation standard, measurement of the total cell volume to prevent inadequate hemodialysis, and infectious control consideration. In the present era, single-use strategy is increasingly adopted due to the decreased cost for dialyzer manufacturing. Environmental concerns of higher solid waste from dialyzer disposal in single-use dialysis should be compared with the liquid waste from reprocessing chemicals along with plastic waste and cardboard in reuse dialysis.

Conclusion: Dialyzer reprocessing with adequate regulation is considered as an acceptable option for cost-effective hemodialysis, compared with the single-use strategy.

Download full-text PDF

Source
http://dx.doi.org/10.1111/sdi.13163DOI Listing

Publication Analysis

Top Keywords

dialyzer reprocessing
20
dialyzer
14
dialyzer reuse
12
single-use strategy
12
effective safe
8
compared single-use
8
reprocessing
6
reprocessing considerations
4
considerations pitfalls
4
pitfalls effective
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!