Balloon-assisted enteroscopy-based endoscopic stricturotomy for deep small bowel strictures from Crohn's disease: First cohort study of a novel approach.

Dig Liver Dis

Department of Small Bowel Endoscopy, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, PR China; Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, PR China; Department of Gastroenterology, Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Nanjing University, Nanjing, PR China; Department of Gastroenterology, the Third Xiangya Hospital of Central South University, Changsha, PR China. Electronic address:

Published: October 2023

Background: There is little data on the role of endoscopic stricturotomy (ES) in treating deep small bowel strictures. We aimed to investigate the efficacy and safety of balloon-assisted enteroscopy-based ES (BAE-based ES) for deep small bowel strictures associated with Crohn's disease (CD).

Methods: This multicentre retrospective cohort study included consecutive patients with CD-associated deep small bowel strictures treated with BAE-based ES between 2017 and 2023. The outcomes included technical success, clinical improvement, surgery-free rate, reintervention-free rate, and adverse events.

Results: Twenty-eight patients with CD underwent 58 BAE-based ES procedures for non-passable deep small bowel strictures, with a median follow-up time of 519.5 days (interquartile range, 306-728 days). Fifty-six (96.0%) procedures were technically successful in 26 (92.9%) patients. Twenty patients (71.4%) showed clinical improvement at week 8. The cumulative surgery-free rate at 1 year was 74.8% (95% confidence interval [CI], 60.3-92.9%). A higher body mass index was associated with a decreased need for surgery (hazard ratio = 0.084, 95% CI, 0.016-0.45, P = 0.0036). Postprocedural adverse events (bleeding and perforation) requiring reintervention occurred in 3.4% of the procedures.

Conclusions: The novel BAE-based ES provides high technical success, favorable efficacy, and safety in CD-associated deep small bowel strictures, which may provide an alternative for endoscopic balloon dilation and surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dld.2023.05.033DOI Listing

Publication Analysis

Top Keywords

deep small
24
small bowel
24
bowel strictures
24
balloon-assisted enteroscopy-based
8
endoscopic stricturotomy
8
crohn's disease
8
cohort study
8
efficacy safety
8
cd-associated deep
8
technical success
8

Similar Publications

With climate extremes' rising frequency and intensity, robust analytical tools are crucial to predict their impacts on terrestrial ecosystems. Machine learning techniques show promise but require well-structured, high-quality, and curated analysis-ready datasets. Earth observation datasets comprehensively monitor ecosystem dynamics and responses to climatic extremes, yet the data complexity can challenge the effectiveness of machine learning models.

View Article and Find Full Text PDF

The Formation and Features of Massive Vacuole Induced by Nutrient Deficiency in Human Embryonic Kidney Cells.

Front Biosci (Landmark Ed)

January 2025

Department of Cardiovascular Medicine, Binzhou Medical University Hospital, 256603 Binzhou, Shandong, China.

Background: Cellular vacuolization is a commonly observed phenomenon under physiological and pathological conditions. However, the mechanisms underlying vacuole formation remain largely unresolved.

Methods: LysoTracker Deep Red probes and Enhanced Green Fluorescent Protein-tagged light chain 3B (LC3B) plasmids were employed to differentiate the types of massive vacuoles.

View Article and Find Full Text PDF

Alginate Hydrogel Beads with a Leakproof Gold Shell for Ultrasound-Triggered Release.

Pharmaceutics

January 2025

Department of Biomedical Engineering, University of Minnesota, 7-105 Hasselmo Hall, 312 Church Street SE, Minneapolis, MN 55455, USA.

Focused ultrasound has advantages as an external stimulus for drug delivery as it is non-invasive, has high precision and can penetrate deep into tissues. Here, we report a gold-plated alginate (ALG) hydrogel system that retains highly water-soluble small-molecule fluorescein for sharp off/on release after ultrasound exposure. The ALG is crosslinked into beads with calcium chloride and layered with a polycation to adjust the surface charge for the adsorption of catalytic platinum nanoparticles (Pt NPs).

View Article and Find Full Text PDF

Dry powder inhalers (DPI's) are becoming increasingly popular due to growing interest in pulmonary drug delivery and their performance is the net result of a series of processes carried out during the formulation development and manufacturing process such as excipient selection, blending, milling, filling, and spray drying. To reach the small airways of the deep lung, the active pharmaceutical ingredients (API) particles need to have an aerodynamic diameter of 1-5 μm to avoid impaction and particle sedimentation in the upper respiratory tract, and due to this small particle size, the powder becomes highly cohesive resulting in poor flow. Therefore, API is usually blended with a coarse carrier to improve flowability, and due to its large size, it is more fluidizable than the micronized drug.

View Article and Find Full Text PDF

Repeated expeditions across various regions of Georgia in the early 2000s led to the identification of 434 wild grapevine individuals ( L. subsp. (C.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!