A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and analysis of a multi-module peristaltic simulator for gastrointestinal research. | LitMetric

Development and analysis of a multi-module peristaltic simulator for gastrointestinal research.

Food Res Int

Department of Biological and Agricultural Engineering, University of California, Davis, USA; Riddet Institute, Palmerston North, New Zealand. Electronic address:

Published: August 2023

Many existing in vitro digestion systems do not accurately represent the peristaltic contractions of the gastrointestinal system; most of the systems that have physiologically-relevant peristaltic contractions have low throughput and can only test one sample at a time. A device has been developed that provides simulated peristaltic contractions for up to 12 digestion modules simultaneously using rollers of varying width to modulate the dynamics of the peristaltic motion. The force applied to a simulated food bolus varied from 2.61 ± 0.03 N to 4.51 ± 0.16 N (p < 0.05) depending on roller width. Video analysis showed that the degree of occlusion of the digestion module varied from 72.1 ± 0.4% to 84.6 ± 1.2% (p < 0.05). A multiphysics, computational fluid dynamics model was created to understand the fluid flow. The fluid flow was also examined experimentally using video analysis of tracer particles. The model-predicted maximum fluid velocity in the peristaltic simulator incorporating the thin rollers was 0.016 m/s, and the corresponding value measured using tracer particles was 0.015 m/s. The occlusion, pressure, and fluid velocity in the new peristaltic simulator fell within physiologically representative ranges. Although no in vitro device perfectly recreates the conditions of the gastrointestinal system, this novel device is a flexible platform for future gastrointestinal research and could allow for high-throughput screening of food materials for health-promoting properties under conditions representative of human gastrointestinal motility.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodres.2023.112877DOI Listing

Publication Analysis

Top Keywords

peristaltic contractions
12
peristaltic
5
development analysis
4
analysis multi-module
4
multi-module peristaltic
4
peristaltic simulator
4
simulator gastrointestinal
4
gastrointestinal existing
4
existing vitro
4
vitro digestion
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!