A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tidal lung hysteresis to interpret PEEP-induced changes in compliance in ARDS patients. | LitMetric

Background: In ARDS, the PEEP level associated with the best respiratory system compliance is often selected; however, intra-tidal recruitment can increase compliance, falsely suggesting improvement in baseline mechanics. Tidal lung hysteresis increases with intra-tidal recruitment and can help interpreting changes in compliance. This study aims to assess tidal recruitment in ARDS patients and to test a combined approach, based on tidal hysteresis and compliance, to interpret decremental PEEP trials.

Methods: A decremental PEEP trial was performed in 38 COVID-19 moderate to severe ARDS patients. At each step, we performed a low-flow inflation-deflation manoeuvre between PEEP and a constant plateau pressure, to measure tidal hysteresis and compliance.

Results: According to changes of tidal hysteresis, three typical patterns were observed: 10 (26%) patients showed consistently high tidal-recruitment, 12 (32%) consistently low tidal-recruitment and 16 (42%) displayed a biphasic pattern moving from low to high tidal-recruitment below a certain PEEP. Compliance increased after 82% of PEEP step decreases and this was associated to a large increase of tidal hysteresis in 44% of cases. Agreement between best compliance and combined approaches was accordingly poor (K = 0.024). The combined approach suggested to increase PEEP in high tidal-recruiters, mainly to keep PEEP constant in biphasic pattern and to decrease PEEP in low tidal-recruiters. PEEP based on the combined approach was associated with lower tidal hysteresis (92.7 ± 20.9 vs. 204.7 ± 110.0 mL; p < 0.001) and lower dissipated energy per breath (0.1 ± 0.1 vs. 0.4 ± 0.2 J; p < 0.001) compared to the best compliance approach. Tidal hysteresis ≥ 100 mL was highly predictive of tidal recruitment at next PEEP step reduction (AUC 0.97; p < 0.001).

Conclusions: Assessment of tidal hysteresis improves the interpretation of decremental PEEP trials and may help limiting tidal recruitment and energy dissipated into the respiratory system during mechanical ventilation of ARDS patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10261834PMC
http://dx.doi.org/10.1186/s13054-023-04506-6DOI Listing

Publication Analysis

Top Keywords

tidal hysteresis
20
ards patients
12
combined approach
12
peep
10
tidal
8
tidal lung
8
lung hysteresis
8
changes compliance
8
intra-tidal recruitment
8
decremental peep
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!