The purpose of this study was to evaluate the added value of the soft tissue image obtained by the one-shot dual-energy subtraction (DES) method using a flat-panel detector compared with the standard image alone in distinguishing calcified from non-calcified nodules on chest radiographs. We evaluated 155 nodules (48 calcified and 107 non-calcified) in 139 patients. Five radiologists (readers 1 - 5) with 26, 14, 8, 6 and 3 years of experience, respectively, evaluated whether the nodules were calcified using chest radiography. CT was used as the gold standard of calcification and non-calcification. Accuracy and area under the receiver operating characteristic curve (AUC) were compared between analyses with and without soft tissue images. The misdiagnosis ratio (false positive plus false negative ratios) when nodules and bones overlapped was also examined. The accuracy of all radiologists increased after adding soft tissue images (readers 1 - 5: 89.7% vs. 92.3% [P = 0.206], 83.2% vs. 87.7% [P = 0.178], 79.4% vs. 92.3% [P < 0.001], 77.4% vs. 87.1% [P = 0.007], and 63.2% vs. 83.2% [P < 0.001], respectively). AUCs for all the readers improved, except for reader 2 (readers 1 - 5: 0.927 vs. 0.937 [P = 0.495], 0.853 vs. 0.834 [P = 0.624], 0.825 vs. 0.878 [P = 0.151], 0.808 vs. 0.896 [P < 0.001], and 0.694 vs. 0.846 [P < 0.001], respectively). The misdiagnosis ratio for nodules that overlapped with the bone decreased after adding soft tissue images in all readers (11.5% vs. 7.6% [P = 0.096], 17.6% vs. 12.2% [P = 0.144], 21.4% vs. 7.6% [P < 0.001], 22.1% vs. 14.5% [P = 0.050] and 35.9% vs. 16.0% [P < 0.001], respectively), particularly that of readers 3 - 5. In conclusion, the soft tissue images obtained using one-shot DES with a flat-panel detector have added value in distinguishing calcified from non-calcified nodules on chest radiographs, especially for less experienced radiologists.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10260954PMC
http://dx.doi.org/10.1038/s41598-023-36785-yDOI Listing

Publication Analysis

Top Keywords

soft tissue
12
one-shot dual-energy
8
dual-energy subtraction
8
chest radiography
8
flat-panel detector
8
distinguishing calcified
8
calcified non-calcified
8
non-calcified nodules
8
nodules calcified
8
readers 1 - 5
8

Similar Publications

Simulations of the Potential for Diffraction Enhanced Imaging at 8 keV using Polycapillary Optics.

Biomed Phys Eng Express

January 2025

Physics Department, University at Albany, 1400 Washington Ave, Albany, New York, 12222-0100, UNITED STATES.

Conventional x-ray radiography relies on attenuation differences in the object, which often results in poor contrast in soft tissues. X-ray phase imaging has the potential to produce higher contrast but can be difficult to utilize. Instead of grating-based techniques, analyzer-based imaging, also known as diffraction enhanced imaging (DEI), uses a monochromator crystal with an analyzer crystal after the object.

View Article and Find Full Text PDF

Modern techniques of rib fracture fixation surgery follow the AO principles of fracture reduction, fixation, and appropriate soft tissue handling. Fixation techniques can be performed using anatomic reduction and rigid fixation, or bridge plate fixation for comminuted fractures. Anatomic and nonanatomic plates can be used, although titanium precontoured locking plates are the most commonly used.

View Article and Find Full Text PDF

[Infrequent association of OEIS complex with a diaphragmatic defect].

Andes Pediatr

August 2023

Programa Madre Canguro /Alto riesgo neonatal Subred Sur-UMHES-MEISSEN, Bogotá, Colombia.

Unlabelled: Omphalocele-exstrophy-imperforate anus-spinal defects (OEIS) complex is a rare entity that presents abdominal wall defects, entails high morbidity and mortality, and requires multidisciplinary management.

Objective: To describe a case with an unusual association between OEIS complex and diaphragmatic hernia and to discuss its pathogenesis and possible association with other midline malformations.

Clinical Case: A preterm female newborn of 33 weeks of gestational age, with prenatal diagnosis of giant omphalocele that, at birth, presented intact amnion coverture containing the entire liver and some bowel loops, open bladder exstrophy and exposed urethral orifices; uterus didelphys, no palpable gonads, and concurrent imaging findings of pelvic soft tissue extrusion, left diaphragmatic hernia (Bochdalek), multiple bone defects, myelomeningocele, and myelocystocele.

View Article and Find Full Text PDF

Thighplasty is a widely performed body contouring procedure, utilizing various surgical techniques for thigh lifting, including medial scar positioning, vertical and horizontal procedures, and liposuction. Despite its popularity, thighplasty is associated with high complication rates and suboptimal postoperative outcomes.This article presents a novel technique: the J medial thighplasty combined with helium plasma radiofrequency technology (HPRF) to address moderate skin and soft-tissue laxity and ptosis in the inner thighs.

View Article and Find Full Text PDF

With the increase of patients with adult congenital heart disease, the number of high-risk multiple redo sternotomies is increasing. Calcified conduit embedded in the sternum or large vessels attached to the sternum presents an especially challenging case. This video tutorial presents a simple safe redo sternotomy technique using an ultrasonic bone scalpel in such high-risk patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!