Purpose: Multichannel Transcranial Magnetic Stimulation (mTMS) [1] is a novel non-invasive brain stimulation technique allowing multiple sites to be stimulated simultaneously or sequentially under electronic control without movement of the coils. To enable simultaneous mTMS and MR imaging, we have designed and constructed a whole-head 28-channel receive-only RF coil at 3T.

Methods: A helmet-shaped structure was designed considering a specific layout for a mTMS system with holes for positioning the TMS units next to the scalp. Diameter of the TMS units defined the diameter of RF loops. The placement of the preamplifiers was designed to minimize possible interactions and to allow straightforward positioning of the mTMS units around the RF coil. Interactions between TMS-MRI were analyzed for the whole-head system extending the results presented in previous publications [2]. Both SNR- and g-factors maps were obtained to compare the imaging performance of the coil with commercial head coils.

Results: Sensitivity losses for the RF elements containing TMS units show a well-defined spatial pattern. Simulations indicate that the losses are predominantly caused by eddy currents on the coil wire windings. The average SNR performance of the TMSMR 28-channel coil is about 66% and 86% of the SNR of the 32/20-channel head coil respectively. The g-factor values of the TMSMR 28-channel coil are similar to the 32-channel coil and significantly better than the 20-channel coil.

Conclusion: We present the TMSMR 28-channel coil, a head RF coil array to be integrated with a multichannel 3-axisTMS coil system, a novel tool that will enable causal mapping of human brain function.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10499022PMC
http://dx.doi.org/10.1016/j.brs.2023.05.025DOI Listing

Publication Analysis

Top Keywords

coil
12
tms units
12
tmsmr 28-channel
12
28-channel coil
12
brain stimulation
8
head coil
8
novel whole-head
4
whole-head coil
4
coil design
4
design tailored
4

Similar Publications

Real-Time Tractography-Assisted Neuronavigation for Transcranial Magnetic Stimulation.

Hum Brain Mapp

January 2025

Department of Neuroscience and Biomedical Engineering, School of Science, Aalto University, Espoo, Finland.

State-of-the-art navigated transcranial magnetic stimulation (nTMS) systems can display the TMS coil position relative to the structural magnetic resonance image (MRI) of the subject's brain and calculate the induced electric field. However, the local effect of TMS propagates via the white-matter network to different areas of the brain, and currently there is no commercial or research neuronavigation system that can highlight in real time the brain's structural connections during TMS. This lack of real-time visualization may overlook critical inter-individual differences in brain connectivity and does not provide the opportunity to target brain networks.

View Article and Find Full Text PDF

Unraveling the protein kinase C/NDRG1 signaling network in breast cancer.

Cell Biosci

December 2024

Department of Biological and Environmental Sciences and Technologies (DiSTeBA), University of Salento, Lecce, Italy.

N-myc downstream-regulated gene 1 (NDRG1) is a member of the NDRG family of intracellular proteins and plays a central role in a wide range of biological processes including stress response, differentiation, and metabolism. The overexpression of NDRG1 is an indicator of poor prognosis in various types of cancer. Here, we found that NDRG1 is an independent prognostic marker of poor outcome in breast cancer (BC).

View Article and Find Full Text PDF

Analysis of the efficacy and factors affecting the prognosis of intracranial dissecting aneurysm treated with multi-stent overlap technique.

BMC Neurol

December 2024

Department of Neurological Surgery, The First College of Clinical Medical Science, China Three Gorges University, Yichang Central People's Hospital, 183 Yiling Avenue, Yichang City, Wujiagang District, China.

Objective: The study aims to identify characteristics that impact the postoperative prognosis and recurrence of intracranial dissecting aneurysms (IDA) patients treated using multi-stent overlapping techniques.

Methods: Clinical data from 69 IDA patients treated with multistate-assisted spring coil embolization at the hospital between January 2017 and October 2023 were retrospectively reviewed, including clinical and imaging data gathered at admission and discharge. The prognosis was determined based on mRS grade at discharge, and the patients were divided into excellent prognosis (mRS 0-2 points) and poor prognosis (mRS 3-6 points).

View Article and Find Full Text PDF

CCfrag: scanning folding potential of coiled-coil fragments with AlphaFold.

Bioinform Adv

December 2024

Department of Protein Evolution, Max Planck Institute for Biology, Tübingen 72076, Germany.

Motivation: Coiled coils are a widespread structural motif consisting of multiple α-helices that wind around a central axis to bury their hydrophobic core. While AlphaFold has emerged as an effective coiled-coil modeling tool, capable of accurately predicting changes in periodicity and core geometry along coiled-coil stalks, it is not without limitations, such as the generation of spuriously bent models and the inability to effectively model globally non-canonical-coiled coils. To overcome these limitations, we investigated whether dividing full-length sequences into fragments would result in better models.

View Article and Find Full Text PDF

The Baveno VII consensus, released in 2023, recommends that the endoscopic treatment of choice for managing bleeding gastric varices (GV) is endoscopic ultrasound (EUS)-guided treatment, specifically EUS-guided cyanoacrylate (CYA) glue injection. This approach has been endorsed due to its efficacy in controlling bleeding while reducing rebleeding rates, compared to other endoscopic techniques. Despite its efficacy, CYA injection for GV has been linked to rare but serious adverse events, such as glue embolization leading to pulmonary embolism, infection/bacteremia, splenic infarction, intra-procedural and post-procedural complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!