Purpose: Tibial bone stress injuries are a common overuse injury among runners and military cadets. Current treatment involves wearing an orthopedic walking boot for 3 to 12 wk, which limits ankle motion and leads to lower limb muscle atrophy. A dynamic ankle orthosis (DAO) was designed to provide a distractive force that offloads in-shoe vertical force and retains sagittal ankle motion during walking. It remains unclear how tibial compressive force is altered by the DAO. This study compared tibial compressive force and ankle motion during walking between the DAO and an orthopedic walking boot.
Methods: Twenty young adults walked on an instrumented treadmill at 1.0 m·s -1 in two brace conditions: DAO and walking boot. Three-dimensional kinematic, ground reaction forces, and in-shoe vertical force data were collected to calculate peak tibial compressive force. Paired t -tests and Cohen's d effect sizes were used to assess mean differences between conditions.
Results: Peak tibial compressive force ( P = 0.023; d = 0.5) and Achilles tendon force ( P = 0.017; d = 0.5) were moderately lower in the DAO compared with the walking boot. Sagittal ankle excursion was 54.9% greater in the DAO compared with the walking boot ( P = 0.05; d = 3.1).
Conclusions: The findings from this study indicated that the DAO moderately reduced tibial compressive force and Achilles tendon force and allowed more sagittal ankle excursion during treadmill walking compared with an orthopedic walking boot.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1249/MSS.0000000000003234 | DOI Listing |
Bone Joint Res
January 2025
Department of Mechanical Engineering & Mechanics, Lehigh University, Bethlehem, Pennsylvania, USA.
Aims: The "2 to 10% strain rule" for fracture healing has been widely interpreted to mean that interfragmentary strain greater than 10% predisposes a fracture to nonunion. This interpretation focuses on the gap-closing strain (axial micromotion divided by gap size), ignoring the region around the gap where osteogenesis typically initiates. The aim of this study was to measure gap-closing and 3D interfragmentary strains in plated ovine osteotomies and associate local strain conditions with callus mineralization.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopedics, The Second Affiliated Hospital of Air Force Military Medical University (Tangdu Hospital), 569 Xinsi Road, Baqiao District, Xi'an City, Shaanxi Province, 710000, China.
Objective: To explore the relationship between meniscus compression and the severity of knee osteoarthritis.
Materials And Methods: A retrospective case-control study included 95 patients with knee osteoarthritis (OA) admitted to our hospital from April 2021 to July 2023, who were grouped into slight protrusion of meniscus group (n = 48) and severe protrusion of meniscus group (n = 47) according to the degree of meniscal extrusion. Various parameters, including Kellgren/Lawrence classification, imaging findings, cartilage damage grading, physical function assessments, and correlation analyses, were used to evaluate the relationship between meniscal extrusion and disease progression.
BMC Musculoskelet Disord
December 2024
Department of Trauma and Microreconstructive Surgery, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, 830054, China.
Background: The purpose of this study was to report the clinical and psychological outcomes of using a locking compression plate (LCP) as a sequential external fixator following the distraction phase in the treatment of tibial bone defects caused by fracture-related infection (FRI).
Methods: We retrospectively analyzed the clinical records and consecutive X-ray images of patients with tibial bone defects who were treated with an LCP as a sequential external fixator following the distraction phase, between June 2017 and December 2022. The ASAMI criteria were applied to assess the bone and functional outcomes, and postoperative complications were evaluated by using the Paley classification.
BMC Musculoskelet Disord
December 2024
Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual & Reality Experimental Education Center for Medical Morphology, School of Basic Medical Sciences, Southern Medical University, No.1023, South Shatai Road, Baiyun District, Guangzhou, Guangdong, 510515, China.
Background: This study investigated the impact of higher interfragmentary compression force (IFCF) on the stability of locking plate fixation in lateral tibial plateau fractures.
Methods: Biomechanical experiments and finite element analysis (FEA) were employed to compare the performance of the AO cancellous lag screw (AOCLS) and a newly developed combined cancellous lag screw (CCLS).
Results: The results demonstrated that the CCLS provided a higher IFCF without the risk of over-screwing, significantly improving fixation stability.
Rev Bras Ortop (Sao Paulo)
November 2024
Universidade do Planalto Catarinense, Lages, SC, Brasil.
Popliteal artery entrapment syndrome has congenital and functional causes. It mostly affects young people. There are six types of popliteal artery entrapment syndrome.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!