Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Ultraviolet lasers are commonly used in flow cytometry to excite fluorochrome molecules with subsequent measurement of the specific fluorescence of individual cells. In this study, the performance of the ultraviolet light scattering (UVLS) in the analysis of individual particles with flow cytometry has been demonstrated for the first time. The main advantage of the UVLS relates to the improvement of the analysis of submicron particles due to the strong dependence of the scattering efficiency on the wavelength of the incident light. In this work, submicron particles were analyzed using a scanning flow cytometer (SFC) that allows measurements of light scattering in an angle-resolved regime. The measured light-scattering profiles of individual particles were utilized in solution of the inverse light-scattering problem to retrieve the particle characteristics using a global optimization. The standard polystyrene microspheres were successfully characterized from the analysis of UVLS which provided the size and refractive index (RI) of individual beads. We believe that the main application of UVLS relates to the analysis of microparticles in a serum, in particular in the analysis of chylomicrons (CMs). We have demonstrated the performance of the UVLS SFC in the analysis of CMs of a donor. The RI versus size scatterplot of CMs was successfully retrieved from the analysis. The current set-up of the SFC has allowed us to characterize individual CMs starting from the size of 160 nm that provides determination of the CM concentration in a serum with flow cytometry. This feature of the UVLS should help with the analysis of lipid metabolism measuring RI and size map evolution after lipase action.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/cyto.a.24769 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!