Background: For lung cancer, circulating tumor markers (TM) are available to guide clinical treatment decisions. To ensure adequate accuracy, pre-analytical instabilities need to be known and addressed in the pre-analytical laboratory protocols.

Objective: This study investigates the pre-analytical stability of CA125, CEA, CYFRA 21.1, HE4 and NSE for the following pre-analytical variables and procedures; i) whole blood stability, ii) serum freeze-thaw cycles, iii) electric vibration mixing and iv) serum storage at different temperatures.

Methods: Left-over patient samples were used and for every investigated variable six patient samples were used and analysed in duplicate. Acceptance criteria were based on analytical performance specifications based on biological variation and significant differences with baseline.

Results: Whole blood was stable for at least 6 hours for all TM except for NSE. Two freeze-thaw cycles were acceptable for all TM except CYFRA 21.1. Electric vibration mixing was allowed for all TM except for CYFRA 21.1. Serum stability at 4°C was 7 days for CEA, CA125, CYFRA 21.1 and HE4 and 4 hours for NSE.

Conclusions: Critical pre-analytical processing step conditions were identified that, if not taken into account, will result in reporting of erroneous TM results.

Download full-text PDF

Source
http://dx.doi.org/10.3233/TUB-220013DOI Listing

Publication Analysis

Top Keywords

cyfra 211
20
pre-analytical stability
8
cea cyfra
8
tumor markers
8
211 he4
8
freeze-thaw cycles
8
electric vibration
8
vibration mixing
8
patient samples
8
pre-analytical
6

Similar Publications

Repurposing bosentan as an anticancer agent: EGFR/ERK/c-Jun modulation inhibits NSCLC tumor growth.

Fundam Clin Pharmacol

February 2025

Department of Pharmacology and Toxicology, Faculty of Pharmacy, Beni-Suef University, Beni-Suef, 62514, Egypt.

Drug repurposing of well-established drugs to be targeted against lung cancer has been a promising strategy. Bosentan is an endothelin 1 (ET-1) blocker widely used in pulmonary hypertension. The current experiment intends to inspect the anticancer and antiangiogenic mechanism of bosentan targeting epidermal growth factor receptor (EGFR) /extra-cellular Signal Regulated Kinase (ERK) /c-Jun/vascular endothelial growth factor (VEGF) carcinogenic pathway.

View Article and Find Full Text PDF

Non-small cell lung cancer (NSCLC) is the predominant form of lung cancer and poses a significant public health challenge. Early detection is crucial for improving patient outcomes, with serum biomarkers such as carcinoembryonic antigen (CEA), squamous cell carcinoma antigen (SCCAg), and cytokeratin fragment 19 (CYFRA 21-1) playing a critical role in early screening and pathological classification of NSCLC. However, due to being mainly based on corresponding antibody binding reactions, existing detection technologies for these serum biomarkers have shortcomings such as complex operations, high false positive rates, and high costs.

View Article and Find Full Text PDF

A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique.

View Article and Find Full Text PDF

: Lung nodules detected by chest computed tomography (CT) often require invasive biopsies for definitive diagnosis, leading to unnecessary procedures for benign lesions. A blood-based biomarker test that predicts lung cancer risk in CT-detected nodules could help stratify patients and direct invasive diagnostics toward high-risk individuals. : In this multicenter, single-blinded clinical trial, we evaluated a test measuring plasma levels of p53, anti-p53 autoantibodies, CYFRA 21-1, and anti-CYFRA 21-1 autoantibodies in patients with CT-detected lung nodules.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the role of serum proteins as biomarkers for early detection of HPV-related cervical cancer, focusing on proteins like CEA, SCCA, HMGB1, and CYFRA 21-1.
  • Analysis of blood samples from 36 cervical cancer patients revealed that CEA was the most frequently detected protein, highlighting variations based on different HPV types.
  • The findings suggest that CEA could serve as a reliable biomarker for cervical cancer, especially in cases linked to HPV-16, which showed the highest response rates among the tested proteins.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!