In studies of the right ventricle the complexities of chamber shape may be overcome by use of multiple tomographic imaging planes. An established protocol for the echocardiographic description of the heart was used to examine the right ventricle in an ordered series of transducer locations and orientations. Diastolic measurements were made of the right ventricular inflow tract, outflow tract, and right ventricular body, and the range and reproducibility of normal values for cavity size and right ventricular free wall thickness were established. These measurements of cavity size in 41 normal subjects were highly reproducible and the views that were used correctly described the truncated and ellipsoidal shape of the right ventricular inflow tract and body with a separately aligned outflow tract. Cavity trabeculation prevented measurement of the free wall thickness in some areas; however, values of nearly twice the previously reported upper limit of normal for anterior regions were measured from the apex or lateral right ventricular wall. These normal data provide a basis for future echocardiographic studies of the right ventricle.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1277383 | PMC |
http://dx.doi.org/10.1136/hrt.56.1.33 | DOI Listing |
PLoS One
January 2025
Electrical, Mechanical & Computer Engineering School, Federal University of Goias, Goiania, Brazil.
This paper proposes the use of artificial intelligence techniques, specifically the nnU-Net convolutional neural network, to improve the identification of left ventricular walls in images of myocardial perfusion scintigraphy, with the objective of improving the diagnosis and treatment of coronary artery disease. The methodology included data collection in a clinical environment, followed by data preparation and analysis using the 3D Slicer Platform for manual segmentation, and subsequently, the application of artificial intelligence models for automated segmentation, focusing on the efficiency of identifying the walls of the left ventricular. A total of 83 clinical routine exams were collected, each exam containing 50 slices, which is 4,150 images.
View Article and Find Full Text PDFCirc Heart Fail
January 2025
First Faculty of Medicine, Biotechnology and Biomedicine Center of the Academy of Sciences and Charles University (BIOCEV), Charles University, Prague, Czech Republic. (M.B., D.L., O.V., J.P.).
Background: Right ventricular dysfunction (RVD) is common in patients with heart failure with reduced ejection fraction, and it is associated with poor prognosis. However, no biomarker reflecting RVD is available for routine clinical use.
Methods: Proteomic analysis of myocardium from the left ventricle and right ventricle (RV) of patients with heart failure with reduced ejection fraction with (n=10) and without RVD (n=10) who underwent heart transplantation was performed.
Echocardiography
January 2025
Department of Ultrasound, The Second Affiliated Hospital of Harbin Medical University, Harbin, China.
Objectives: Supra-normal left ventricular ejection fraction (snLVEF) represents a heterogeneous group with distinct prognoses. Left atrial (LA) strain, measured by speckle tracking echocardiography (STE), is a validated prognostic indicator. This study aimed to evaluate LA and left ventricular (LV) mechanical strains in hypertensive patients with snLVEF.
View Article and Find Full Text PDFJACC Case Rep
December 2024
Jesselson Integrated Heart Center, The Eisenberg R&D Authority, Shaare Zedek Medical Center, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel.
Objective: This study sought to present the endovascular approach of transcatheter aspiration using the FlowTriever (Inari Medical) aspiration system for high surgical risk patients with right-sided infective endocarditis.
Key Steps: General anesthesia and transesophageal echocardiogram guidance; ultrasonography-guided femoral vein access, preclosure sutures, and insertion of a 24-F sheath; insertion of straight 24-F aspiration cannula over a stiff wire, parked in the superior vena cava; introduction of a 20-F curved cannula inside the 24-F cannula to create a telescopic assembly; accurate positioning using the right ventricle inflow/outflow projection in biplane mode; adjustment of the curved cannula radius by sliding the inner cannula in and out inside the mother cannula; manual aspiration of the vegetation; Postaspiration transesophageal echocardiogram assessment.
Potential Pitfalls: Avoid leaflet and annular injury and account for potential embolization.
A 65-year-old patient was admitted to the Institute with complaints of shortness of breath, palpitation, and limb edema. Comorbidities were type 2 diabetes mellitus, gout, obesity. Echo: left ventricular ejection fraction 22%, left ventricular aneurysm (LVA), floating thrombus 5.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!