The degradation of trichloroethylene (TCE) vapors by zero-valent Iron-Copper (Fe-Cu) and Iron-Nickel (Fe-Ni) bimetals with 1%, 5% and 20% weight content (%wt) of Cu or Ni was tested in anaerobic batch vapor systems carried out at ambient room temperature (20 ± 2 °C) under partially saturated conditions. The concentrations of TCE and byproducts were determined at discrete reaction time intervals (4 h-7 days) by analyzing the headspace vapors. In all the experiments, up to 99.9% degradation of TCE in the gas phase was achieved after 2-4 days with zero-order TCE degradation kinetic constants in the range of 134-332 g md. Fe-Ni showed a higher reactivity towards TCE vapors compared to Fe-Cu, with up to 99.9% TCE dechlorination after 2 days of reaction, i.e., significantly higher than zero-valent iron alone that in previous studies was found to achieve comparable TCE degradation after minimum 2 weeks of reaction. The only detectable byproducts of the reactions were C-C hydrocarbons. Neither vinyl chloride or dichloroethylene peaks were detected in the tested conditions above their method quantification limits that were in the order of 0.01 g m. In view of using the tested bimetals in horizontal permeable reactive barriers (HPRBs) placed in the unsaturated zone to treat chlorinated solvent vapors emitted from contaminated groundwater, the experimental results obtained were integrated into a simple analytical model to simulate the reactive transport of vapors through the barrier. It was found that an HPRB of 20 cm could be potentially effective to ensure TCE vapors reduction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jconhyd.2023.104204 | DOI Listing |
Environ Pollut
January 2025
Biological Sciences, Wayne State University, Detroit, MI, USA; Center for Leadership in Environmental Awareness and Research, Wayne State University, Detroit, MI, USA. Electronic address:
Adv Healthc Mater
October 2024
Departments of Diagnostic Radiology, Surgery, Chemical and Biomolecular Engineering, and Biomedical Engineering, Yong Loo Lin School of Medicine and College of Design and Engineering, National University of Singapore, Singapore, 119074, Singapore.
Environ Pollut
December 2024
College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, 100049, China. Electronic address:
To analyze the surface cumulative mass of VOCs from residual sources in dual-media fractured rocks and assess environmental health risks, complex 3D numerical models were constructed. These models comprehensively considered fracture-rock interactions, density-driven effects, and surface pressure fluctuations. The investigation identified the key control factors affecting surface cumulative mass, including the fracture aperture, pollutant source location, fracture density, and so on.
View Article and Find Full Text PDFGround Water Monit Remediat
March 2024
US EPA, ORD, CEMM, EPD.
Understanding vapor intrusion (VI) temporal variability is key for the design of sampling strategies intended to assess reasonable maximum exposure of indoor air concentrations of volatile organic compounds (VOCs) as well as risk evaluation and mitigation planning. VI temporal variability has previously been shown to be dependent on the complex interactions of multiple independent variables-meteorological, hydrogeological, and human behavioral. Several meteorological variables, including barometric pressure, wind speed, and rainfall, are linked during tropical and extratropical storm events.
View Article and Find Full Text PDFTalanta
August 2024
Department of Chemistry, Louisville, KY, 40292, USA. Electronic address:
Whereas the close associations of cesium ion with organochlorine compounds have been previously documented, the present report is the first attempt to exploit these interactions to create a trichloroethylene (TCE)-selective sensor. Gold monolayer-protected clusters peripherally functionalized with Cs ions were used to prepare a chemiresistance film on MEMS-fabricated interdigitated electrodes. Vapor sensing properties of the cesium-rich chemiresistor were determined using a panel of chlorinated hydrocarbons including TCE as well as polar and non-polar VOCs for comparison.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!