This study aims to characterize contact forces between humans and tools during activities of daily living (ADL) to provide information to a personal care robot. The study was conducted on non-impaired subjects to capture various static and dynamic force levels when making contact with three different robotic tools, each designed to perform an ADL task: hair brushing, face wiping, and face shaving. The static trial of the study involved 21 participants. Forces were collected at fixed locations for each task and used to develop models for each participant. Extraction of the maximum force levels was performed for both the maximum and desired levels of force. The dynamic trial involved 24 individuals. Participants were asked to maintain a comfortable level of force for the duration of their contact with the tool as the robot moved along its path to perform the ADL task. For the static and dynamic trials, higher forces were observed during hair brushing compared to the other two tasks. It was observed that the hair brushing task force at a specific contact point has an overall maximum of 55.66 N, while the maximum forces detected in the face wiping and face shaving tasks were 36.40 and 11.11 N, respectively. The forces collected were analyzed, and no trends were found relating the contact forces to the gender, height, or weight of the subjects. Based on the analysis of the results, recommendations have been made to enhance the force safety limits for the personal care robot working environment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350725 | PMC |
http://dx.doi.org/10.1177/09544119231179568 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Department of Cardiology, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, Yunnan, P.R. China.
Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Section of Laboratory for Animal Experiments, Institute of Medical Science, Medical Research Support Center, Nihon University, School of Medicine, Tokyo, Japan.
Background: Neither the actual in vivo tissue temperatures reached with a novel contact force sensing catheter with a mesh-shaped irrigation tip (TactiFlex SE, Abbott) nor the safety profile has been elucidated.
Methods: In a porcine model (n = 8), thermocouples were implanted epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava following a right thoracotomy. After chest closure, endocardial ablation was conducted near the thermocouples under fluoroscopic guidance.
J Neurophysiol
January 2025
Neuroscience Research Institute, Seoul National University Medical Research Center, Seoul, Korea.
Previous studies have shown that high-gamma (HG) activity in the primary visual cortex (V1) has distinct higher (broadband) and lower (narrowband) components with different functions and origins. However, it is unclear whether a similar segregation exists in the primary somatosensory cortex (S1), and the origins and roles of HG activity in S1 remain unknown. Here, we investigate the functional roles and origins of HG activity in S1 during tactile stimulation in humans and a rat model.
View Article and Find Full Text PDFMed Oral Patol Oral Cir Bucal
January 2025
Rua Monsenhor Furtado, 1273 Rodolfo Teófilo, Fortaleza CEP: 60.430-355. Ceará, Brasil
Background: The presence of mandibular third molars has been associated with the risk of mandibular fractures, highlighting the need for comprehensive studies considering the interaction with other mandibular structures. This study investigates how mandibular third molars and neighboring tissues can influence the structural fragility of the mandible using finite element analysis.
Material And Methods: A finite element analysis study following the guidelines proposed by RIFEM 1.
Ann Biomed Eng
January 2025
Department of Mechanical and Industrial Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA.
Purpose: To evaluate the population variation in head-to-helmet contact forces in helmet users.
Methods: Four different size Kevlar composite helmets were instrumented with contact pressure sensors and chinstrap tension meters. A total number of 89 volunteers (25 female and 64 male volunteers) participated in the study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!