Fully 3D-Printed Dry EEG Electrodes.

Sensors (Basel)

School of Computer Science, The University of Sydney, Sydney, NSW 2006, Australia.

Published: May 2023

Electroencephalography (EEG) is used to detect brain activity by recording electrical signals across various points on the scalp. Recent technological advancement has allowed brain signals to be monitored continuously through the long-term usage of EEG wearables. However, current EEG electrodes are not able to cater to different anatomical features, lifestyles, and personal preferences, suggesting the need for customisable electrodes. Despite previous efforts to create customisable EEG electrodes through 3D printing, additional processing after printing is often needed to achieve the required electrical properties. Although fabricating EEG electrodes entirely through 3D printing with a conductive material would eliminate the need for further processing, fully 3D-printed EEG electrodes have not been seen in previous studies. In this study, we investigate the feasibility of using a low-cost setup and a conductive filament, Multi3D Electrifi, to 3D print EEG electrodes. Our results show that the contact impedance between the printed electrodes and an artificial phantom scalp is under 550 Ω, with phase change of smaller than -30∘, for all design configurations for frequencies ranging from 20 Hz to 10 kHz. In addition, the difference in contact impedance between electrodes with different numbers of pins is under 200 Ω for all test frequencies. Through a preliminary functional test that monitored the alpha signals (7-13 Hz) of a participant in eye-open and eye-closed states, we show that alpha activity can be identified using the printed electrodes. This work demonstrates that fully 3D-printed electrodes have the capability of acquiring relatively high-quality EEG signals.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10255664PMC
http://dx.doi.org/10.3390/s23115175DOI Listing

Publication Analysis

Top Keywords

eeg electrodes
24
fully 3d-printed
12
electrodes
11
eeg
9
contact impedance
8
printed electrodes
8
3d-printed dry
4
dry eeg
4
electrodes electroencephalography
4
electroencephalography eeg
4

Similar Publications

Anterior cruciate ligament injuries (ACLi) impact football players substantially leading to performance declines and premature career endings. Emerging evidence suggests that ACLi should be viewed not merely as peripheral injuries but as complex conditions with neurophysiological aspects. The objective of the present study was to compare kicking performance and associated cortical activity between injured and healthy players.

View Article and Find Full Text PDF

Meta analysis of resting frontal alpha asymmetry as a biomarker of depression.

Npj Ment Health Res

January 2025

Clinical Research Center for Mental Disorders, Shanghai Pudong New Area Mental Health Center, School of Medicine, Tongji University, Shanghai, 200124, China.

This meta-analysis investigated resting frontal alpha asymmetry (FAA) as a potential biomarker for major depressive disorder (MDD). Studies included articles utilizing FAA measure involving EEG electrodes (F3/F4, F7/F8, or Fp1/Fp2) and covering both MDD and controls. Hedges' d was calculated from FAA means and standard deviations (SDs).

View Article and Find Full Text PDF

Fatigue driving is one of the potential factors threatening road safety, and monitoring drivers' mental state through electroencephalography (EEG) can effectively prevent such risks. In this paper, a new model, DE-GFRJMCMC, is proposed for selecting critical channels and optimal feature subsets from EEG data to improve the accuracy of fatigue driving recognition. The model is validated on the SEED-VIG dataset.

View Article and Find Full Text PDF

Transformer-based neural speech decoding from surface and depth electrode signals.

J Neural Eng

January 2025

Electrical and Computer Engineering Department, New York University, 370 Jay Street, Brooklyn, New York, New York, 10012-1126, UNITED STATES.

This study investigates speech decoding from neural signals captured by intracranial electrodes. Most prior works can only work with electrodes on a 2D grid (i.e.

View Article and Find Full Text PDF

Objective: Inclusion of individualised electrical conductivities of head tissues is crucial for the accuracy of electrical source imaging techniques based on electro/magnetoencephalography and the efficacy of transcranial electrical stimulation. Parametric electrical impedance tomography (pEIT) is a method to cheaply and non-invasively estimate them using electrode arrays on the scalp to apply currents and measure the resulting potential distribution. Conductivities are then estimated by iteratively fitting a forward model to the measurements, incurring a prohibitive computational cost that is generally lowered at the expense of accuracy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!