A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On the Use of Deuterated Organic Solvents without TMS to Report H/C NMR Spectral Data of Organic Compounds: Current State of the Method, Its Pitfalls and Benefits, and Related Issues. | LitMetric

On the Use of Deuterated Organic Solvents without TMS to Report H/C NMR Spectral Data of Organic Compounds: Current State of the Method, Its Pitfalls and Benefits, and Related Issues.

Molecules

Theoretical and Structural Chemistry Group, Department of Physical Chemistry, Faculty of Chemistry, University of Lodz, 163/165 Pomorska, 90-236 Łódź, Poland.

Published: May 2023

AI Article Synopsis

  • The discussion critiques Method A for referencing NMR spectra using residual H and C signals of deuterated organic solvents, highlighting its imperfections and variability across different solvents.
  • Recommended changes to improve accuracy include utilizing dilute solutions and reporting δ values to the nearest 0.001/0.01 ppm, accommodating the influence of concentration and solvent type on spectral values.
  • The potential errors and discrepancies in δ readings, particularly for CDCl, underscore the need for more reliable reference methods, suggesting the classical use of an internal standard (Method B) as preferable in complex organic analyses.

Article Abstract

The quite popular, simple but imperfect method of referencing NMR spectra to residual H and C signals of TMS-free deuterated organic solvents (referred to as Method A) is critically discussed for six commonly used NMR solvents with respect to their δ and δ values that exist in the literature. Taking into account the most reliable data, it was possible to recommend 'best' δ values for such secondary internal standards. The position of these reference points on the δ scale strongly depends on the concentration and type of analyte under study and the solvent medium used. For some solvents, chemically induced shifts (CISs) of residual H lines were considered, also taking into account the formation of 1:1 molecular complexes (for CDCl). Typical potential errors that can occur as a result of improper application of Method A are considered in detail. An overview of all found δ values adopted by users of this method revealed a discrepancy of up to 1.9 ppm in δ reported for CDCl, most likely caused by the CIS mentioned above. The drawbacks of Method A are discussed in relation to the classical use of an internal standard (Method B), two 'instrumental' schemes in which Method A is often implicitly applied, that is, the default Method C using H lock frequencies and Method D based on values, recommended by the IUPAC but only occasionally used for H/C spectra, and external referencing (Method E). Analysis of current needs and opportunities for NMR spectrometers led to the conclusion that, for the most accurate application of Method A, it is necessary to (a) use dilute solutions in a single NMR solvent and (b) to report δ data applied for the reference H/C signals to the nearest 0.001/0.01 ppm to ensure the precise characterization of new synthesized or isolated organic systems, especially those with complex or unexpected structures. However, the use of TMS in Method B is strongly recommended in all such cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10254718PMC
http://dx.doi.org/10.3390/molecules28114369DOI Listing

Publication Analysis

Top Keywords

method
13
deuterated organic
8
organic solvents
8
application method
8
nmr
5
solvents
4
solvents tms
4
tms report
4
report h/c
4
h/c nmr
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!