Body Composition Is Related to Maximal Effort Treadmill Test Time in Firefighters.

Healthcare (Basel)

Human Performance & Sport Physiology Laboratory, Department of Rehabilitation Sciences & Technology, University of Wisconsin-Milwaukee, Milwaukee, WI 53211, USA.

Published: May 2023

Firefighting tasks may require near maximal levels of cardiorespiratory fitness. Previous research has indicated that body fat percentage (BF%) and aerobic capacity (VO) are related to the performance of firefighting tasks. Since a standard submaximal treadmill test for firefighters is terminated at 85% of maximal heart rate (MHR), key performance information relating to maximal cardiorespiratory effort may not be measured in a submaximal test. The purpose of this study was to examine the relationships between body composition and time spent running at intensities greater that 85% MHR. Height, weight, body mass index (BMI; kg/m), BF%, MHR (bpm), VO (mL/kg/min), predicted VO (P-VO; mL/kg/min), submaximal treadmill test time (WFI Test Time; min), and maximal treadmill test time (WFI Test Time; min) were collected in fifteen active-duty firefighters. The results indicated that significant relationships ( < 0.05) existed between BF% and VO, BF% and WFI Test Time, BF% and T, and VO and WFI Test Time. P-VO was not significantly different than VO, and the WFI Test Time was significantly longer than the WFI Test Time. These results indicate that a submaximal treadmill test may reasonably predict VO, but key information about physiological work at intensities greater than 85% MHR may be missed when using submaximal effort tests.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10252530PMC
http://dx.doi.org/10.3390/healthcare11111607DOI Listing

Publication Analysis

Top Keywords

test time
36
wfi test
24
treadmill test
20
test
12
submaximal treadmill
12
time
10
body composition
8
firefighting tasks
8
intensities greater
8
greater 85%
8

Similar Publications

Nurse Leader Perspectives and Experiences on Caregiver Support Following a Serious Medical Error.

J Nurs Adm

December 2024

Author Affiliations: Assistant Professor (Dr Prothero) and Nurse (Sorhus and Huefner), College of Nursing, Brigham Young University, Provo, Utah.

Objective: This study explored nurse leaders' perspectives and experiences in supporting nurses following a serious medical error.

Background: Appropriate support is crucial for nurses following an error. Authentic leadership provides an environment of psychological safety and establishes a patient safety culture.

View Article and Find Full Text PDF

Objective: The physician-scientist workforce is shrinking in the United States. Academic otologists/neurotologists face a diverse set of barriers to successful careers. We aimed to characterize the factors affecting contemporary otology/neurotology surgeon-scientists.

View Article and Find Full Text PDF

Study Question: Does a human fallopian tube (HFT) organoid model offer a favourable apical environment for human sperm survival and motility?

Summary Answer: After differentiation, the apical compartment of a new HFT organoid model provides a favourable environment for sperm motility, which is better than commercial media.

What Is Known Already: HFTs are the site of major events that are crucial for achieving an ongoing pregnancy, such as gamete survival and competence, fertilization steps, and preimplantation embryo development. In order to better understand the tubal physiology and tubal factors involved in these reproductive functions, and to improve still suboptimal in vitro conditions for gamete preparation and embryo culture during IVF, we sought to develop an HFT organoid model from isolated adult stem cells to allow spermatozoa co-culture in the apical compartment.

View Article and Find Full Text PDF

Significance: Optimal meibography utilization and interpretation are hindered due to poor lid presentation, blurry images, or image artifacts and the challenges of applying clinical grading scales. These results, using the largest image dataset analyzed to date, demonstrate development of algorithms that provide standardized, real-time inference that addresses all of these limitations.

Purpose: This study aimed to develop and validate an algorithmic pipeline to automate and standardize meibomian gland absence assessment and interpretation.

View Article and Find Full Text PDF

High-performance and cost-effective hole-collecting materials (HCMs) are indispensable for commercially viable perovskite solar cells (PSCs). Here, we report an anchorable HCM composed of a triazatruxene core connected with three alkyl carboxylic acid groups (). In contrast to the phosphonic acid-containing tripodal analog (), molecules can form a hydrophilic monolayer on a transparent conducting oxide surface, which is beneficial for subsequent perovskite film deposition in the traditional layer-by-layer fabrication process.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!